Multifield Calculation and Analysis of Excitation Winding Interturn Short Circuit Fault in Turbo-Generator

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Circulating current analysis between strands in armature winding of a turbo-generator using analytical model

In this paper, the circulating current analysis between strands is studied while considering the different transpositions in the active part and without considering the transposition in the end winding region. First, this analysis is done while only considering the slot region, and then the end winding region is added to the model. The model used for this analysis is a circuit model, including ...

متن کامل

Stator Fault Detection in Induction Machines by Parameter Estimation Using Adaptive Kalman Filter

This paper presents a parametric low differential order model, suitable for mathematically analysis for Induction Machines with faulty stator. An adaptive Kalman filter is proposed for recursively estimating the states and parameters of continuous–time model with discrete measurements for fault detection ends. Typical motor faults as interturn short circuit and increased winding resistance ...

متن کامل

Short Circuit Calculation Methods

All electrical systems are susceptible to short circuits and the abnormal current levels they create. These currents can produce considerable thermal and mechanical stresses in electrical distribution equipment. Therefore, it's important to protect personnel and equipment by calculating short-circuit currents during system upgrade and design. Because these calculations are life-safety related, ...

متن کامل

A Comprehensive Mathematical Model for Analysis of WR-Resolvers under Stator Short Circuit Fault

Wound-Rotor (WR) resolvers are the most widely used position sensors in applications with harsh environmental conditions. However, their performance is exposed to failure due to the high risk of short circuit (SC) fault. Although the output current of the resolver is negligible, its thin copper wires increase the probability of the short circuit fault. To avoid the propagation of the turn-to-tu...

متن کامل

Short Winding Fault Detection Using Park’s Vector

The subject of on-line detection of short winding fault in three-phase induction motors is discussed, and a noninvasive approach, based on the computer-aided monitoring of the stator current Park’s Vector, is introduced. The park's vector representation is obtained using Virtual instrument. The Virtual Instrument is obtained by programming in Labview software. The laboratory tests were conducte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Energies

سال: 2018

ISSN: 1996-1073

DOI: 10.3390/en11102626