Multicenter evaluation of the Glucometer Elite XL meter, an instrument specifically designed for use with neonates.
OBJECTIVE To evaluate the clinical performance of the Glucometer Elite XL Diabetes Care System in neonatal settings using a multicenter study RESEARCH DESIGN AND METHODS A total of 388 blood specimens from 333 neonates were included in the study. A capillary or arterial sample was analyzed for determination of glucose with the Glucometer Elite XL system by an attending trained nurse. Through ...
متن کاملthe use of appropriate madm model for ranking the vendors of mci equipments using fuzzy approach
abstract nowadays, the science of decision making has been paid to more attention due to the complexity of the problems of suppliers selection. as known, one of the efficient tools in economic and human resources development is the extension of communication networks in developing countries. so, the proper selection of suppliers of tc equipments is of concern very much. in this study, a ...
15 صفحه اولUsability of cushions designed specifically for car industries’ assembly lines
Background: Ergonomics is a science that provides methods of creating reasonable adaption between occupation and worker by improving usability through consideration of job demands and human ability to satisfy them. A deep understanding of user’s thoughts on and attitudes toward utilizing a tool could improve its design. In the present study, two cushions designed particularly for one of c...
متن کاملNewly designed instrument for desalination: Comparison with dialysis bag
All desalination methods which are currently used have limitations. A newly designed instrument by Zare A.M. was tested and compared with currently used method in Razi Vaccine and Serum Research Institute(RVSRI). Samples of anti snake venom for desalination was provided by department of anti-serum, RVSRI. Parameters included in this study were time and water consumption during desalination pr...
متن کاملthe efficacy of an instrument designed for specific self – afficacy measurment in patients with mi
the efficacy of an instrument designed for specific self – afficacy measurment in patients with mi zand s [1] *, rafiei m [2] received: 9 apr , 2013 accepted: 15 jun , 2013 abstract background & aims : f or efficient evaluation of their beliefs in patients with heart failure, there is a need to use a tool with scientific principles of psychometrics. in our country because of the abs...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Diabetes Care
سال: 2000
ISSN: 0149-5992,1935-5548
DOI: 10.2337/diacare.23.8.1149