Multicenter evaluation of the Bayer Immuno 1™ CA 15-3™ assay
نویسندگان
چکیده
منابع مشابه
Multicenter evaluation of the performance characteristics of the bayer VERSANT HCV RNA 3.0 assay (bDNA).
In this multicenter evaluation, the VERSANT HCV RNA 3.0 Assay (bDNA) (Bayer Diagnostics, Tarrytown, N.Y.) was shown to have excellent reproducibility, linearity, and analytical sensitivity across specimen collection matrices (serum, EDTA, ACD-A), and hepatitis C virus (HCV) genotypes 1 to 6. The VERSANT HCV bDNA Assay has a reportable range of 615 to 7690000 (7.69 x 10(6)) IU/ml. The total coef...
متن کاملAnalytical performance of Bayer Immuno 1 estradiol and progesterone assays.
We evaluated the analytical performance of new estradiol and progesterone assays performed on the Bayer Immuno 1 system. Within-run and between-day CVs for estradiol at concentrations of 116.8-6645.8 pmol/L were < or = 6.4% and for 5.54-103.95 nmol/L progesterone were < or = 7.7%, thus meeting published analytical goals. The detection limits (2 SDs from mean of zero calibrator) were 27.1 pmol/L...
متن کاملMulticenter evaluation of the Verigene Clostridium difficile nucleic acid assay.
The Verigene Clostridium difficile Nucleic Acid test (Verigene CDF test) (Nanosphere, Northbrook, IL) is a multiplex qualitative PCR assay that utilizes a nanoparticle-based array hybridization method to detect C. difficile tcdA and tcdB in fecal specimens. In addition, the assay detects binary toxin gene sequences and the single base pair deletion at nucleotide 117 (Δ 117) in tcdC to provide a...
متن کاملthe evaluation of language related engagment and task related engagment with the purpose of investigating the effect of metatalk and task typology
abstract while task-based instruction is considered as the most effective way to learn a language in the related literature, it is oversimplified on various grounds. different variables may affect how students are engaged with not only the language but also with the task itself. the present study was conducted to investigate language and task related engagement on the basis of the task typolog...
15 صفحه اولMulticenter evaluation of an automated assay for troponin I.
BACKGROUND Cardiac troponin I (cTnI) is a powerful tool to aid in the diagnosis of myocardial infarction and cardiac muscle damage. We describe an assay that overcomes problems of early assays that were often affected by cTnI degradation, assay interference, poor sensitivity, and imprecision. METHODS The analytical performance of the Access AccuTnI assay (Beckman Coulter) was evaluated at fiv...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Clinical Chemistry
سال: 1998
ISSN: 0009-9147,1530-8561
DOI: 10.1093/clinchem/44.4.765