Multi-wavelength spectrophotometry of EX Hydrae
نویسندگان
چکیده
منابع مشابه
Multi-wavelength spectrophotometry of EX Hydrae
We present phase-resolved infrared and optical spectrophotometry of the intermediate polar EXHya supplemented by archival ultraviolet data. The spin-modulated emission from the accretion funnel and the emission from the accretion disk or ring contain substantial optically thin components. The white dwarf dominates the unmodulated flux in the ultraviolet and is identified by numerous absorption ...
متن کاملTW Hydrae: multi-wavelength interferometry of a transition disk
For over a decade, the structure of the inner “hole” in the transition disk around TW Hydrae has been a subject of debate. To probe the innermost regions of the protoplanetary disk, observations at the highest possible spatial resolution are required. We present new interferometric data of TW Hya from near-infrared to millimeter wavelengths. We confront existing models of the disk structure wit...
متن کاملORFEUS II and IUE Spectroscopy of EX Hydrae
Using five high-resolution (λ/∆λ ≈ 3000) FUV (λλ = 910–1210 Å) spectra acquired in 1996 December during the flight of the ORFEUS-SPAS II mission, 47 archival IUE short-wavelength UV (λλ = 1150–1950 Å) spectra, and archival EUVE deep survey photometry (λλ ≈ 70–200 Å), we present a detailed picture of the behavior of the magnetic cataclysmic variable EX Hydrae in the vacuum ultraviolet. Like HUT ...
متن کاملUpdated Spin Ephemeris for the Cataclysmic Variable Ex Hydrae
Recent satellite observations demonstrate that the phase of maximum flux of the 67 min spin modulation of the white dwarf in the cataclysmic variable EX Hya is drifting away from the optical quadratic ephemeris of Hellier & Sproats (1992, hereafter HS92). Relative to that ephemeris, the peak of the spin-phase extreme ultraviolet (EUV) flux modulation measured with the Extreme Ultraviolet Explor...
متن کاملMethemoglobin in blood as determined by double-wavelength spectrophotometry.
We describe spectrophotometric determination of methemoglobin (Met-Hb) in blood by absorbance differences at two wavelengths (characteristic of the instrument used) in the 500-600 nm region. Blood is diluted 100- to 200-fold with a solution containing KCN and carbon monoxide to convert hemoglobin to carboxyhemoglobin and Met-Hb to cyanomethemoglobin (CN-Met-Hb). Carboxyhemoglobin has the same a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Astronomy & Astrophysics
سال: 2002
ISSN: 0004-6361,1432-0746
DOI: 10.1051/0004-6361:20011655