Multi Frequency Phase Fluorimetry (MFPF) for Oxygen Partial Pressure Measurement: Ex Vivo Validation by Polarographic Clark-Type Electrode
نویسندگان
چکیده
منابع مشابه
Multi Frequency Phase Fluorimetry (MFPF) for Oxygen Partial Pressure Measurement: Ex Vivo Validation by Polarographic Clark-Type Electrode
BACKGROUND Measurement of partial pressure of oxygen (PO2) at high temporal resolution remains a technological challenge. This study introduces a novel PO2 sensing technology based on Multi-Frequency Phase Fluorimetry (MFPF). The aim was to validate MFPF against polarographic Clark-type electrode (CTE) PO2 measurements. METHODOLOGY/PRINCIPAL FINDINGS MFPF technology was first investigated in ...
متن کاملPolarographic Oxygen Electrode
A method has been developed for the continuous monitoring of oxygen tension in solutions and gases. The oxygen is reduced at a platinum surface which is covered with a plastic membrane. The silver-silver oxide reference electrode is also included under the membrane. Drift is less than 10 per cent for a period of days, and temperature compcnsation is possible. A number of uses to which it has be...
متن کاملmodeling loss data by phase-type distribution
بیمه گران همیشه بابت خسارات بیمه نامه های تحت پوشش خود نگران بوده و روش هایی را جستجو می کنند که بتوانند داده های خسارات گذشته را با هدف اتخاذ یک تصمیم بهینه مدل بندی نمایند. در این پژوهش توزیع های فیزتایپ در مدل بندی داده های خسارات معرفی شده که شامل استنباط آماری مربوطه و استفاده از الگوریتم em در برآورد پارامترهای توزیع است. در پایان امکان استفاده از این توزیع در مدل بندی داده های گروه بندی ...
In vivo oxygen uptake into the human cornea.
PURPOSE We provide a new procedure to quantify in situ corneal oxygen uptake using the micropolarographic Clark electrode. METHODS Traditionally, upon placing a membrane-covered Clark microelectrode onto a human cornea, the resulting polarographic signal is interpreted as the oxygen partial pressure at the anterior corneal surface. However, the Clark electrode operates at a limiting current. ...
متن کاملNon-invasive measurement of the superficial cortical oxygen partial pressure.
We present a non invasive fluorescein based method to measure and visualise the partial oxygen pressure of the rat cortex in a 2D picture. We studied 10 Wistar rats. A trepanation was done over the hemisphere and the dura was opened. A PMMA cylinder with a calibrated optical membrane was fixed over the surface of the brain. The CCD camera with the light source is placed over the cylinder. This ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: PLoS ONE
سال: 2013
ISSN: 1932-6203
DOI: 10.1371/journal.pone.0060591