منابع مشابه
Isotropic resolution in Diffusion Weighted Imaging using 3D multi-slab, multi-echo Echo Planar Imaging
INTRODUCTION Diffusion weighted Magnetic Resonance Imaging (DWI) is usually performed using a 2D single shot echo planar imaging technique, because it generates good SNR, short scan times and is immune to phase differences between diffusion-encoded excitations. 2D DWEPI can be acquired with a reasonably high in-plane resolution, especially if parallel imaging is used to reduce the geometric dis...
متن کاملCorrection for EPI distortions using multi-echo gradient-echo imaging.
A novel and effective technique is described for distortion correction in echo planar imaging (EPI) utilizing the field maps derived from multi-echo gradient-echo images. The distortions from different off-resonance related factors such as field inhomogeneity, eddy current effect, radiofrequency pulse frequency offset, and chemical shift effect can be simultaneously reduced to a great extent. W...
متن کاملMulti-Echo based Correlated Spectroscopic Imaging
Introduction – Despite the many advantages of Chemical Shift Imaging (CSI) [1] over ordinary single voxel spectroscopy, its onedimensional (1D) spectra are still limited by severe spectral overlap, which can complicate quantification of metabolites. Twodimensional Magnetic Resonance Spectroscopy (2D MRS) aims to alleviate the quantification problems due to spectral overlap by pushing resonances...
متن کاملMulti-echo IDEAL Cardiac Water-Fat Imaging
Introduction In cardiac magnetic resonance imaging, separation of water and fat signals is important for improved visualization of enhancing myocardium and pericardial disease, as well as direct visualization of fat in pathologies such as arrythmogenic right ventricular cardiomyopathy (ARVC), fatty tumors, and fatty infiltration of chronic myocardial infarctions. Fat can appear similar to slow ...
متن کاملImproved susceptibility weighted imaging method using multi-echo acquisition.
PURPOSE To introduce novel acquisition and postprocessing approaches for susceptibility weighted imaging (SWI) to remove background field inhomogeneity artifacts in both magnitude and phase data. METHODS The proposed method acquires three echoes in a three-dimensional gradient echo (GRE) sequence, with a field compensation gradient (z-shim gradient) applied to the third echo. The artifacts in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Physics
سال: 2021
ISSN: ['2624-8174']
DOI: https://doi.org/10.1103/physics.14.65