Multi-channel frequency shift measurement circuit with high sampling rate for QCM odor sensors
نویسندگان
چکیده
منابع مشابه
A measurement system for odor classification based on the dynamic response of QCM sensors
In this paper, an innovative measurement system for odor classification, based on quartz crystal microbalances (QCMs), is presented. The application proposed in this paper is the detection of typical wine aroma compounds in mixtures containing ethanol. In QCM sensors, the sensitive layer is, e.g., a polymeric layer deposited on a quartz surface. Chemical mixtures are sorbed in the sensitive lay...
متن کاملHigh-frequency phase shift measurement greatly enhances the sensitivity of QCM immunosensors.
In spite of being widely used for in liquid biosensing applications, sensitivity improvement of conventional (5-20MHz) quartz crystal microbalance (QCM) sensors remains an unsolved challenging task. With the help of a new electronic characterization approach based on phase change measurements at a constant fixed frequency, a highly sensitive and versatile high fundamental frequency (HFF) QCM im...
متن کاملA multi-channel multi-sampling rate theorem
The Möbius function is utilised to propose a class of multi-channel, multi-sampling rate theorems. Our construction facilitates a parallel decomposition of the Fourier transform into an array of general integral transform operators. A practical example is discussed which employs a complex square wave biorthonormal basis.
متن کاملMulti-Channel Sampling on Shift-Invariant Spaces with Frame Generators
Let φ be a continuous function in L(R) such that the sequence {φ(t− n)}n∈Z is a frame sequence in L(R) and assume that the shift-invariant space V (φ) generated by φ has a multi-banded spectrum σ(V ). The main aim in this paper is to derive a multi-channel sampling theory for the shift-invariant space V (φ). By using a type of Fourier duality between the spaces V (φ) and L[0, 2π] we find necess...
متن کاملAn Fpga-based System for the Measurement of Frequency Noise and Resolution of Qcm Sensors
−− The use of Quartz Crystal Oscillators (QCM) as high accuracy microbalance sensors is limited by the frequency noise present in the circuit. This work deals with the design and implementation of an FPGA-based system for the real-time measurement of the frequency noise and resolution of QCM sensors. This reconfigurable system integrates the frequency measurement and the mass resolution computa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEJ Transactions on Sensors and Micromachines
سال: 2002
ISSN: 1341-8939,1347-5525
DOI: 10.1541/ieejsmas.122.16