Analytical Challenges and Strategies in FE-EPMA
Unquestionably, since their introduction one decade ago, field emission (FE) electron microprobes have pushed the boundaries of electron probe microanalysis (EPMA) by offering new possibilities to characterize smaller features. As with conventional microprobes, the proper selection of the analytical conditions (beam energy, beam current, acquisition time, x-ray line) is essential to obtain an a...
متن کاملHigh Energy Beam-beam Effects in Clic
In order to achieve high luminosity, the Compact Linear Collider (CLIC) has to be operated in the highbeamstrahlung regime at centre-of-mass energies in the few TeV range. Beam-beam effects for this case are simulated. The dependence of luminosity, luminosity spectrum and background conditions on the different beam parameters is investigated. In particular the effect of beam size, waist shift a...
متن کاملMitigating Thermal Beam Damage with Metallic Coats in Low Voltage FEG-EPMA of Geological Materials
Field emission gun electronprobe microanalysis (FEG-EPMA) provides the analyst with the opportunity to characterize very small volumes of material. Using a low voltage source the irradiated volume is submicron. It is well known that some geological phases e.g. volcanic glass, carbonates, phosphates, hydrous silicates suffer beam damage under high beam current condition [e.g.1,2] and several aut...
متن کاملBeam Energy
The energy loss due to the excitation of parasitic modes in the SPEAR II rf cavities and vacuum chamber components has been measured by observing the shift in synchronous phase angle as a function of circulating beam current and accelerating cavity voltage. The resulting parasitic mode loss resistance is 5 Mn at a bunch length of 6.5 cm. The loss resistance varies with bunch length oZ approxima...
متن کاملStrategies for Low Accelerating Voltage X-ray Microanalysis of Sub-Micrometer Features with the FE-EPMA
X-ray microanalyses of sub-micrometer features require that a lower accelerating voltage be used. This reduction in the accelerating voltage reduces the penetrating distance of the beam electrons and thereby reduces the analytical volume. Two general strategies have been proposed for achieving the smallest analytical volume. The first approach involves significantly reducing the accelerating vo...