Multi-beam Echo Sounding and Seafloor Imaging
نویسندگان
چکیده
منابع مشابه
Isotropic resolution in Diffusion Weighted Imaging using 3D multi-slab, multi-echo Echo Planar Imaging
INTRODUCTION Diffusion weighted Magnetic Resonance Imaging (DWI) is usually performed using a 2D single shot echo planar imaging technique, because it generates good SNR, short scan times and is immune to phase differences between diffusion-encoded excitations. 2D DWEPI can be acquired with a reasonably high in-plane resolution, especially if parallel imaging is used to reduce the geometric dis...
متن کاملHawaiian Hot-spot Swell Structure from Seafloor MT Sounding
Seafloor magnetotelluric (MT) data were collected at seven sites across the Hawaiian hot spot swell, spread approximately evenly between 120 and 800 km southwest of the HawaiianEmperor Island chain. All data are consistent with an electrical strike direction of 300◦, aligned along the seamount chain, and are well fit using two dimensional (2D) inversion. The major features of the 2D electrical ...
متن کاملA Seafloor Magnetotelluric Sounding in the Tasman Sea
This paper reports an analysis of electromagnetic data from a site occupied on the floor of the Tasman Sea during an Australia-U.S. research program, the Tasman Project of Seafloor Magnetotelluric Exploration. This site (37ø33'S, 155ø58'E, depth 4450 m) is in the central portion of the Tasman Sea, and near both a fossil spreading ridge and the Tasmantid Seamount Chain. The extensive electric an...
متن کاملCorrection for EPI distortions using multi-echo gradient-echo imaging.
A novel and effective technique is described for distortion correction in echo planar imaging (EPI) utilizing the field maps derived from multi-echo gradient-echo images. The distortions from different off-resonance related factors such as field inhomogeneity, eddy current effect, radiofrequency pulse frequency offset, and chemical shift effect can be simultaneously reduced to a great extent. W...
متن کاملMulti-Echo based Correlated Spectroscopic Imaging
Introduction – Despite the many advantages of Chemical Shift Imaging (CSI) [1] over ordinary single voxel spectroscopy, its onedimensional (1D) spectra are still limited by severe spectral overlap, which can complicate quantification of metabolites. Twodimensional Magnetic Resonance Spectroscopy (2D MRS) aims to alleviate the quantification problems due to spectral overlap by pushing resonances...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Geography (Chigaku Zasshi)
سال: 2000
ISSN: 0022-135X,1884-0884
DOI: 10.5026/jgeography.109.6_874