MRI of frozen tissue demonstrates a phase shift
نویسندگان
چکیده
منابع مشابه
Chemical shift-induced phase errors in phase-contrast MRI.
Phase-contrast magnetic resonance imaging is subject to numerous sources of error, which decrease clinical confidence in the reported measures. This work outlines how stationary perivascular fat can impart a significant chemical shift induced phase-contrast magnetic resonance imaging measurement error using computational simulations, in vitro, and in vivo experiments. This chemical shift error ...
متن کاملDigital Binary Phase-shift Keyed Signal Detector
We have developed the effective algorithm for detecting digital binary phase-shift keyed signals. This algorithm requires a small number of arithmetic operations over the signal period. It can be relatively easy implemented based on the modern programmable logic devices. It also provides high interference immunity by identifying signal presence when signal-to-noise ratio is much less that its w...
متن کاملA Novel Metamaterial Microelectromechanical Systems Phase Shifter with High Phase Shift and High Bandwidth
In this paper, new topology of phase shifter is proposed that uses advantage of metamaterial and MEMS technology. The phase shifter is switched between two states of RH- and LH-TL having frequency passband unlike other proposed metamaterials which create the maximum phase shift from one unitcell. Analysis and design approach of the phase shifter is presented and the structure is simulated using...
متن کاملCompressed Sensing: a Paradigm Shift in MRI
Reducing the complexity and length of examinations has been a major direction of research in magnetic resonance imaging (MRI) in recent years. With the introduction of the Dot engines, the complexity of MR examinations could be reduced through automatization and guidance, providing standardized and time-efficient workflows. Considerable effort has also been spent on developing methods to speed ...
متن کاملInvestigating myocardial motion by MRI using tissue phase mapping.
OBJECTIVE Velocity-encoded phase contrast magnetic resonance imaging (MRI) provides a tool to quantify regional myocardial wall motion of the entire heart. It allows the acquisition of three-directional velocity vector fields with high spatial resolution that reflect the temporal evolution of myocardial velocities over the cardiac cycle. In contrast to other imaging modalities such as echocardi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Magnetic Resonance in Medicine
سال: 2011
ISSN: 0740-3194
DOI: 10.1002/mrm.22953