MRI‐based polymer gel dosimetry for validating plans with multiple matrices in Gamma Knife stereotactic radiosurgery

One of treatment planning techniques with Leksell GammaPlan (LGP) for Gamma Knife stereotactic radiosurgery (GKSRS) uses multiple matrices with multiple dose prescriptions. Computational complexity increases when shots are placed in multiple matrices with different grid sizes. Hence, the experimental validation of LGP calculated dose distributions is needed for those cases. For the current stud...

متن کامل

MAGAT gel and EBT2 film‐based dosimetry for evaluating source plugging‐based treatment plan in Gamma Knife stereotactic radiosurgery

This work illustrates a procedure to assess the overall accuracy associated with Gamma Knife treatment planning using plugging. The main role of source plugging or blocking is to create dose falloff in the junction between a target and a critical structure. We report the use of MAGAT gel dosimeter for verification of an experimental treatment plan based on plugging. The polymer gel contained in...

متن کامل

Uncertainty Analysis in MRI-based Polymer Gel Dosimetry

Background: Polymer gel dosimeters combined with magnetic resonance imaging (MRI) can be used for dose verification of advanced radiation therapy techniques. However, the uncertainty of dose map measured by gel dosimeter should be known. The purpose of this study is to investigate the uncertainty related to calibration curve and MRI protocol for MAGIC (Methacrylic and Ascorbic acid in Gelatin I...

متن کامل

Outcomes of Gamma Knife Radiosurgery in Patients With Parasagittal Meningioma

Background & Aim: The treatment of Parasagittal Meningioma (PSM) is always a challenge, especially when the tumor has already invaded the critical structures like venous sinuses. This study aims at evaluating the outcomes of Gamma Knife Radiosurgery (GKRS) in patients with PSM. Methods and Materials/Patients: In this descriptive retrospective study, we reviewed the medical records of 61 patien...

متن کامل

Gamma knife stereotactic radiosurgery for radiation-induced meningiomas.

BACKGROUND Radiation-induced meningiomas present a unique clinical dilemma given the fact that patients with these tumors have often received a prior full course of radiotherapy. As such, traditional radiotherapy is limited by lifetime tissue tolerances to radiation, leaving surgery and radiosurgery as attractive treatment options. OBJECTIVES To ascertain the safety and efficacy of Gamma Knif...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Applied Clinical Medical Physics

سال: 2011

ISSN: 1526-9914

DOI: 10.1120/jacmp.v12i2.3333