MR Angiography acceleration techniques with iterative reconstructions: the IT-TWIST sequence

نویسندگان

چکیده

In recent years MR Angiography allowed to assess blood vessels and flow in a non-invasive way. The aim of our work was illunstrate modern technique, the 4D Iterative reconstruction Time resolved angiography With Interleaved Stochastic Trajectories (IT-TWIST), capable generate angiograms with high spatial temporal resolution, providing multiple continuous post-contrastographic sets images. Technological physical characteristics are reported detail consequent advantages summarized.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improving Dynamic MR Angiography: Iterative TWIST

Nowadays, many vascular territories are explored non-invasively for the purpose of diagnosis, therapy planning and surveillance of vascular disease. Invasive catheter angiography is almost exclusively being used during therapy and intervention. However, the benefits of invasive approaches include the ability to visualize dynamics of applied dye and may therefore provide additional information o...

متن کامل

Acceleration Techniques for Newton's Non-linear Iterative Scheme Acceleration Techniques for Newton's Non-linear Iterative Scheme Acceleration Techniques for Newton's Non-linear Iterative Scheme

The solution of non-linear sets of algebraic equations is usually obtained by the Newton's method, exhibiting quadratic convergence. For practical simulations, a signiicant computational eeort consists in the evaluation of the Jacobian matrices. In this paper, we propose and experiment various methods to speed the convergence process either by re-using information from previous iterates or by b...

متن کامل

syngo TWIST for Dynamic Time-Resolved MR Angiography

92 www.siemens.com/magnetom-world MAGNETOM FLASH 3/2006 Introduction Siemens, a leader in advanced engineering as well as applications development, has made 3D dynamic imaging available in the late 90s for the MAGNETOM Vision. The speed of dynamic imaging got an extra boost with the strong 40 mT/m gradients available with the MAGNETOM Sonata. Since then, dynamic imaging has gone through several...

متن کامل

Iterative Soft-Thresholding Reconstruction for Time-of-Flight MR Angiography

Introduction: Time-of-Flight MR angiography (TOF-MRA) is a non-invasive technique that utilizes the signal enhancement due to blood inflow effects for imaging the blood vessel anatomy. Vascular images are inherently sparse and can be made even sparser in a suitable transform domain (e.g. wavelet transform), making MR angiography a natural application of Compressed Sensing (CS) [1]. There are tw...

متن کامل

Dedicated Calf MRA at 3T: Comparison of time-resolved MR Angiography with interleaved stochastic trajectories (TWIST) with standard high-resolution 3D contrast enhance MR Angiography (HR ceMRA)

¶ Figure 3: Calf station of left lower limb in patient with normal runoff arteries. (A) TWIST demonstrates focal occlusion of the distal anterior tibial artery (arrow) and a high grade stenosis of the distal posterior tibial artery (arrowhead) (B) HR ceMRA demonstrating normally appearing runoff arteries. Dedicated Calf MRA at 3T: Comparison of time-resolved MR Angiography with interleaved stoc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of advanced health care

سال: 2021

ISSN: ['2612-1344']

DOI: https://doi.org/10.36017/jahc2102-003