Motionless Polarizing Structured Illumination Microscopy
نویسندگان
چکیده
منابع مشابه
Plasmonic structured illumination microscopy.
We propose a super resolution imaging technique called plasmonic structured illumination microscopy (PSIM), which combines the structured illumination microscopy technique with the tunable surface plasmon interference. Because of the high-resolution enabled by using surface plasmon interference as an illumination source, PSIM possesses higher image resolving power compared with conventional str...
متن کاملStructured line illumination Raman microscopy
In the last couple of decades, the spatial resolution in optical microscopy has increased to unprecedented levels by exploiting the fluorescence properties of the probe. At about the same time, Raman imaging techniques have emerged as a way to image inherent chemical information in a sample without using fluorescent probes. However, in many applications, the achievable resolution is limited to ...
متن کاملFrontiers in structured illumination microscopy
At the start of this millennium, the principles of structured illumination microscopy (SIM) had been established and the concept of resolution doubling demonstrated experimentally in two dimensions. Breathtaking advances have since taken place, making SIM one of the most powerful and versatile superresolution methods available today, routinely used in the study of biochemical processes in labor...
متن کاملStructured illumination temporal compressive microscopy.
We present a compressive video microscope based on structured illumination with incoherent light source. The source-side illumination coding scheme allows the emission photons being collected by the full aperture of the microscope objective, and thus is suitable for the fluorescence readout mode. A 2-step iterative reconstruction algorithm, termed BWISE, has been developed to address the mismat...
متن کاملSpeed limits of structured illumination microscopy.
A theoretical framework for widefield structured illumination microscopy (SIM) reconstruction from fewer than the commonly used nine raw frame acquisitions is introduced and applied in silico and in vitro. The proposed scheme avoids the recording of redundant spatial frequency components, which was necessary in previous SIM algorithms. This allows for gentler superresolution imaging at faster s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Sensors
سال: 2021
ISSN: 1424-8220
DOI: 10.3390/s21082837