Motion Automated Perimetry Identifies Early Glaucomatous Field Defects
نویسندگان
چکیده
منابع مشابه
Motion automated perimetry identifies early glaucomatous field defects.
OBJECTIVE To determine if motion automated perimetry can identify early glaucomatous visual field defects in patients with suspected glaucoma (by disc), those with ocular hypertension, and those with primary open-angle glaucoma. METHODS Motion automated perimetry, a foveally centered motion test, and standard visual field tests were conducted on one randomly selected eye of normal patients (n...
متن کاملQuantification of glaucomatous visual field defects with automated perimetry.
A method to quantify different glaucomatous visual field defects is presented. Three visual field indices are calculated: the short-term fluctuation, the mean defect, and the corrected loss variation. The method was applied to visual fields tested with program JO on the Octopus automated perimeter. The indices of 130 glaucoma suspects and 50 glaucoma patients were compared with 100 normal contr...
متن کاملDetection of central visual field defects in early glaucomatous eyes: Comparison of Humphrey and Octopus perimetry
PURPOSE To compare the detection rate of central visual field defect (CVFD) between the 30-degree Octopus G1 program (Dynamic strategy) and the HFA 10-2 SITA-Standard test in early glaucoma eyes not showing any CVFD on the HFA 24-2 SITA-Standard test. METHODS One eye of 41 early glaucoma patients without CVFD in the central 10° on HFA 24-2 test was tested with both the HFA 10-2 test and the O...
متن کاملComparison of visual evoked potentials, automated perimetry and frequency-doubling perimetry in early detection of glaucomatous visual field loss.
The present study compares frequency-doubling perimetry (FDP), automated perimetry (AP) and visual evoked potentials (VEP) for their ability to diagnose early glaucoma. In present study 224 patients of Clinic for Eye Diseases, Clinical Hospital "Sestre Milosrdnice" that had diagnosis of open angle glaucoma and glaucomatous visual field loss proven by automated static perimetry on only one eye w...
متن کامل[Sensitivity of size I stimulus in achromatic automated perimetry for detection of glaucomatous visual field defects: a comparative analysis with short wavelength automated perimetry and standard automated perimetry (SITA)].
PURPOSE To compare sensitivity and specificity of achromatic perimetry with size I stimulus (WW-I) with standard automated perimetry (SITA strategy) and blue on yellow perimetry (SWAP) for early diagnosis of glaucoma. METHODS Seventy-three eyes of 73 suspects, glaucomatous and normal subjects underwent automated perimetry with SITA 24-2, WW-I and SWAP. After application of specific criteria o...