deficiency. It is not applicable to newborn or mass screening with use of ifiterpaper specimens, but is satisfactory for liquid urine screening. In one variant of sulfite oxidase deficiency, due to a defect of its molybdate cofactor metabolism, the concentration of uric acid in serum is decreased. Thus, an unexplained low serum uric acid, especially in a young patient with neurologic abnormalit...
متن کاملAscorbic acid interference in reagent-strip reactions for assay of urinary glucose and hemoglobin.
Vitamin C (ascorbic acid), commonly taken as a dietary supplement and excreted in the urine, can interfere with peroxidase redox indicator systems such as those used in reagent-strip tests for urinary glucose and hemoglobin. We investigated whether the concentrations of ascorbic acid in urine after modest supplementary doses of vitamin C are high enough to interfere with such dipstick tests. Af...
متن کاملA reagent strip for measuring the specific gravity of urine.
A solid-phase reagent for determination of urinary specific gravity (relative density) is described. This reagent strip, similar to others in the "N-Multistix" series (Ames), contains a polyacid whose acidity is sensitive to the ionic concentration in the urine in which it is immersed. As the acidity of the polyacid changes, pH changes are detected by a pH indicator within the reagent strip. In...
متن کاملA dry-reagent strip for quantifying carbamazepine evaluated.
We examined a new colorimetric homogeneous immunoassay for carbamazepine based on the apoenzyme reactivation immunoassay system (ARIS) principle. The test, in dry-reagent strip format, is to be used with the Ames Seralyzer reflectance photometer. Within-run CVs (n = 20) were 3.0%, 2.7%, and 2.8% at 3.0, 6.1, and 12.1 mg/L; between-run CVs (n = 15, in 15 days) were 4.1%, 2.7%, and 1.9% at 6.0, 9...
متن کاملapplication of upfc based on svpwm for power quality improvement
در سالهای اخیر،اختلالات کیفیت توان مهمترین موضوع می باشد که محققان زیادی را برای پیدا کردن راه حلی برای حل آن علاقه مند ساخته است.امروزه کیفیت توان در سیستم قدرت برای مراکز صنعتی،تجاری وکاربردهای بیمارستانی مسئله مهمی می باشد.مشکل ولتاژمثل شرایط افت ولتاژواضافه جریان ناشی از اتصال کوتاه مدار یا وقوع خطا در سیستم بیشتر مورد توجه می باشد. برای مطالعه افت ولتاژ واضافه جریان،محققان زیادی کار کرده ...
15 صفحه اولذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Clinical Chemistry
سال: 1983
ISSN: 0009-9147,1530-8561
DOI: 10.1093/clinchem/29.1.212a