Abstract Introduction: This is the second of two papers giving an overview use Monte-Carlo techniques for radiotherapy applications. Methods: The first paper gave introduction and introduced some codes that are available to user wishing model different aspects treatment. It also aims serve as a useful companion curated collection on have been published in this journal. Results Conclusions: focuses application specific problems radiotherapy. These include imaging beam production, brachytherapy, phantom patient dosimetry, detector modelling track structure calculations micro-dosimetry, nano-dosimetry radiobiology.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monte Carlo and experimental relative dose determination for an Iridium-192 source in water phantom

Background: Monte Carlo and experimental relative dose determination in a water phantom, due to a high dose rate (HDR) 192Ir source is presented for real energy spectrum and monochromatic at 356 keV. Materials and Methods: The dose distribution has been calculated around the 192Ir located in the center of 30 cm ×30 cm ×30 cm water phantom using MCNP4C code by Monte Carlo method. Relati...

متن کامل

Monte Carlo calculations of dose distribution for the treatment of gastric cancer with proton therapy

Proton therapy is a common form of external radiation therapy based on the manipulation of Bragg peak of this beam, it can treat the tumor by delivering high levels of doses to it, while protecting surrounding healthy tissues against radiation. In this work, the dose distribution of proton and secondary particles such as neutrons, photons, electrons and positrons in gastric cancer proton therap...

متن کامل

High-performance computing for Monte Carlo radiotherapy calculations.

We report on the RTGrid project, which investigates approaches for using high-performance computing infrastructures, such as the grid, in order to reduce the turnaround time of Monte Carlo (MC) simulation-based radiotherapy treatment planning. The main aim of this project is to render accurate dose calculations using MC simulations clinically feasible. To this end, we have successfully implemen...

متن کامل

A Track-repeating Algorithm for Fast Monte Carlo Dose Calculations of Proton Radiotherapy.

Monte Carlo codes are utilized for accurate dose calculations in proton radiation therapy research. While they are superior in accuracy to commonly used analytical dose calculations, they require significantly longer computation times. The aim of this work is to characterize a Monte Carlo track-repeating algorithm to increase computation speed without compromising dosimetric accuracy. The track...

متن کامل

Modeling and dose calculations of a pure beta emitting 32P coated stent for intracoronary brachytherapy by Monte Carlo code

Background: Recently, different investigators have studied the possibility of radiation therapy in restenosis prevention and have shown promising results. In this study a unique radioactive source for intra vascular brachytherapy (IVBT) was investigated. The two-dimensional dose distribution in water for a 32P IVBT stent has been calculated. The pure beta emitter source 32P has been co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Radiotherapy in Practice

سال: 2023

ISSN: ['1460-3969', '1467-1131']

DOI: https://doi.org/10.1017/s1460396923000080