Monte Carlo Study of a New Mobile Electron Accelerator Head for Intra Operative Radiation Therapy (IORT)
نویسندگان
چکیده
منابع مشابه
Monte Carlo Simulation of the Electron Beams Produced by a Linear Accelerator for Intra- Operative Radiation Therapy
In this work, organized as a short review, we present some results obtained by applying the Monte Carlo techniques in the Intra-Operative Radiation Therapy (IORT). The electron beams generated by the NOVAC7 IORT accelerator have been simulated using BEAMnrc/EGSnrc Monte Carlo code, the dose distributions and water-to-air stopping power ratios being later calculated with the associated software ...
متن کاملMonte Carlo Simulation of Electron Beams produced by LIAC Intraoperative Radiation Therapy Accelerator
Background: One of the main problems of dedicated IORT accelerators is to determine dosimetric characteristics of the electron beams. Monte Carlo simulation of IORT accelerator head and produced beam will be useful to improve the accuracy of beam dosimetry.Materials and Methods: Liac accelerator head was modeled using the BEAMnrcMonte Carlo simulation system. Phase-space files were generated at...
متن کاملA Monte Carlo simulation study on the effectiveness of electron filters designed for telecobalt radiation therapy treatment
Background: The aim of present study was to analyze the effectiveness of electron filters in the Telecobalt radiotherapy treatment by simulation technique. Materials and Methods: The BEAMnrc Monte Carlo code was used to simulate the electron filters of thickness of 0.5 gm/cm2 below the trimmer bar for 35 × 35 cm2 field size in Theratron Equinox-80 telecobalt unit. The electron filters were mad...
متن کاملmonte carlo simulation of electron beams produced by liac intraoperative radiation therapy accelerator
background: one of the main problems of dedicated iort accelerators is to determine dosimetric characteristics of the electron beams. monte carlo simulation of iort accelerator head and produced beam will be useful to improve the accuracy of beam dosimetry. materials and methods: liac accelerator head was modeled using the beamnrcmonte carlo simulation system. phase-space files were generated a...
متن کاملEvaluation putty metal as internal shield for patient protection of electron therapy by Monte Carlo study
Introduction: In this study, a specific combination (70% W 18.61% Ni and 11.39% C) of lead free and flexible putty metal is introduced and validated as internal shielding by Mont Carlo study Materials and Methods: To evaluate putty metal as an internal shielding by Mont Carlo study Varian 2100 C/D was validated within measurement and then by given energy spect...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Progress in Nuclear Science and Technology
سال: 2011
ISSN: 2185-4823
DOI: 10.15669/pnst.2.181