Monte Carlo simulations to replace film dosimetry in IMRT verification

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monte Carlo simulations to replace film dosimetry in IMRT verification.

Patient-specific verification of intensity-modulated radiation therapy (IMRT) plans can be done by dosimetric measurements or by independent dose or monitor unit calculations. The aim of this study was the clinical evaluation of IMRT verification based on a fast Monte Carlo (MC) program with regard to possible benefits compared to commonly used film dosimetry. 25 head-and-neck IMRT plans were r...

متن کامل

Monte Carlo portal dosimetry for segmented IMRT verification using the SLIC

By comparing predicted dose images with physically acquired images, radiotherapy fields may be verified. A good portal dose verification chain should be accurate and unrestricted in terms of gantry angle and patient-imager air gap distance. We present latest enhancements and rigorous tests of a portal dose prediction framework based on Monte Carlo (MC) radiation transport. We also present initi...

متن کامل

Configurational Temperature Verification of Monte Carlo Simulations

A new diagnostic that is useful for checking the algorithmic correctness of Monte Carlo computer programs is presented. The check is made by comparing the Boltzmann temperature, which is input to the program and used to accept or reject moves, with a configurational temperature k T B config = ∇ ∇ q q Φ Φ 2 2 . Here, Φ is the potential energy of the system and ∇q represents the dimensionless gra...

متن کامل

3D VMAT Verification Based on Monte Carlo Log File Simulation with Experimental Feedback from Film Dosimetry

A model based on a specific phantom, called QuAArC, has been designed for the evaluation of planning and verification systems of complex radiotherapy treatments, such as volumetric modulated arc therapy (VMAT). This model uses the high accuracy provided by the Monte Carlo (MC) simulation of log files and allows the experimental feedback from the high spatial resolution of films hosted in QuAArC...

متن کامل

Monte Carlo investigation of collapsed versus rotated IMRT plan verification

IMRT QA requires, among other tests, a time-consuming process of measuring the absorbed dose, at least to a point, in a high-dose, low-dose-gradient region. Some clinics use a technique of measuring this dose with all beams delivered at a single gantry angle (collapsed delivery), as opposed to the beams delivered at the planned gantry angle (rotated delivery). We examined, established, and opti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Zeitschrift für Medizinische Physik

سال: 2011

ISSN: 0939-3889

DOI: 10.1016/j.zemedi.2010.05.002