Monte Carlo Simulation to Test the Effectiveness of Crystal Detector Length for PHITS-Based PET Modality
نویسندگان
چکیده
PET (Positron-emission tomography) is used to determine physiological and metabolic functions in the body. Monte Carlo simulation an important part of imaging, Particle Heavy Ion Transport code System (PHITS) a platform that can be perform simulations. This study uses based on PHITS range gamma absorption with energy 511 keV scintillation detector crystal material. The determines effective length modality. process carried out by shooting Gamma at various types materials, which are materials crystals. this NaI (Sodium Iodide), BaF2 (Barium Florida), BGO (Bismuth Germanate), GSO (Gadolinium Oxyorthosilicate), considering their atomic number density. material capable absorbing radiation detailed lengths for each 0.26 cm; 0.25 cm crystals; 0.1cm 0.18 from smaller than commercially available (range 1-3 cm). Based data, most crystal.
منابع مشابه
A performance study of the conceptual implementation of the GEM-tracking detector in Monte Carlo simulation
PANDA experiment (antiProton ANnihilation at DArmstadt) is one of the key projects of the future FAIR facilities to investigate the reactions of antiprotons with protons and nuclear targets. experiment is designed to serve as a completely extraordinary physical potential due to exploiting the availability of cold and high-intensity beams of antiprotons. One of the significant parts of the ...
متن کاملMonte Carlo and Detector Simulation in Oop*
Object-Oriented Programming techniques are explored with an eye towards applications in High Energy Physics codes. Two prototype examples are given: MCOOP (a particle Monte Carlo generator) and GISMO (a detector simulation/analysis package).
متن کاملA New Approach for Monte Carlo Simulation of RAFT Polymerization
In this work, based on experimental observations and exact theoretical predictions, the kinetic scheme of RAFT polymerization is extended to a wider range of reactions such as irreversible intermediate radical terminations and reversible transfer reactions. The reactions which have been labeled as kinetic scheme are the more probable existing reactions as the theoretical point of view. The ...
متن کاملComparison of TOF-PET and Bremsstrahlung SPECT images of Yttrium-90: A Monte Carlo Simulation Study
Objective(s): Yttrium-90 (90Y) is a beta particle nuclide used in targeted radionuclide therapy which is available to both single-photon emission computed tomography (SPECT) and time-of-flight (TOF) positron emission tomography (PET) imaging. The purpose of this study was to assess the image quality of PET and Bremsstrahlung SPECT by simulating PET and SPECT images of 90Y using Monte Carlo simu...
متن کاملThe Influence of Crystal Size and Material on Intercrystal Scattering and Parallax in PET Block Detectors: A Monte Carlo Study
Introduction: In this study, we utilized the MCNP4C Monte Carlo code to quantitatively evaluate the influence of crystal size and material on intercrystal scatter and parallax effects. Materials and Methods: For each of the 5 selected crystals (BGO, LSO, LYSO, LuAP, GSO), transport of 511 keV photons originating from a point source and incident on the central cry...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: JPFT (Jurnal Pendidikan Fisika dan Teknologi)
سال: 2023
ISSN: ['2407-6902', '2614-5618']
DOI: https://doi.org/10.29303/jpft.v9i1.4896