Monte Carlo simulation of a scintillation crystal read by a SiPM with GATE

نویسندگان

چکیده

Silicon photomultipliers (SiPMs) have recently emerged as a replacement for photomultiplier tubes (PMTs) light detection in many applications, including high-energy physics and medical imaging. Recently, detailed Monte Carlo simulation of SiPMs has been implemented GATE to quantify the impact SiPM specifications on linearity, energy time resolution scintillation crystal read by SiPM. In this paper, simulations LYSO coupled are compared measurements. The spectra 241Am 22Na radioactive sources found agree with less than 2% difference. linearity response is duly affected saturation and, seen above 511 keV our configuration, it slightly enhanced generation crosstalk. Furthermore, an over-voltage close that recommended manufacturer, all noise contribute about equally degradation at low energies, which downgraded more 15% 60 keV, but higher energies. addition, show crosstalk plays important role installation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rabbit internal dosimetry for iodine-131 using GATE Monte Carlo simulation code: a preclinical trial

Introduction: One of the main concerns in administration of radiotracers, especially in therapeutic arm, is the amount of delivered dose to the different organs. Individual variations of anatomy, physiology and underlying pathology in the patients lead to alteration of administered activity. In the current study we preclinically applied internal dosimetry using an animal mod...

متن کامل

A Monte Carlo Simulation of Photon Beam Generated by a Linear Accelerator

ntroduction:  Monte  Carlo  simulation  is  the  most  accurate  method  of  simulating  radiation  transport  and  predicting doses at different points of interest in radiotherapy. A great advantage of the Monte Carlo method  compared  to  the  deterministic  methods  is  the  ability  to  deal  accurately  with  any  complex  geometry.  Its  disadvantage is the extremely long computing time r...

متن کامل

A New Approach for Monte Carlo Simulation of RAFT Polymerization

In this work, based on experimental observations and exact theoretical predictions, the kinetic scheme of RAFT polymerization is extended to a wider range of reactions such as irreversible intermediate radical terminations and reversible transfer reactions. The reactions which have been labeled as kinetic scheme are the more probable existing reactions as the theoretical point of view. The ...

متن کامل

a comparison between gate and mcnpx monte carlo codes in simulation of medical linear accelerator

radiotherapy dose calculations can be evaluated by monte carlo (mc) simulations with acceptable accuracy for dose prediction in complicated treatment plans. in this work, standard, livermore and penelope electromagnetic (em) physics packages of geant4 application for tomographic emission (gate) 6.1 were compared versus monte carlo n-particle extended (mcnpx) 2.6 in simulation of 6 mv photon lin...

متن کامل

Validation of the GATE Monte Carlo simulation platform for modelling a CsI(Tl) scintillation camera dedicated to small-animal imaging.

Monte Carlo simulations are increasingly used in scintigraphic imaging to model imaging systems and to develop and assess tomographic reconstruction algorithms and correction methods for improved image quantitation. GATE (GEANT4 application for tomographic emission) is a new Monte Carlo simulation platform based on GEANT4 dedicated to nuclear imaging applications. This paper describes the GATE ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Nuclear Instruments and Methods in Physics Research

سال: 2023

ISSN: ['1872-9576', '0168-9002']

DOI: https://doi.org/10.1016/j.nima.2022.167905