Monte Carlo modeling of ultrasound probes for image guided radiotherapy
نویسندگان
چکیده
منابع مشابه
Image-guided radiotherapy for prostate cancer using transperineal ultrasound
During a course of external beam radiotherapy the prostate gland moves both between radiotherapy fractions (interfractional motion) and during treatment (intrafractional motion). Some of this motion is related to changes in rectal and bladder filling, and movements are more marked in the antero-posterior direction as a result of rectal filling variability, compared to laterally and superoinferi...
متن کاملA fast model for prediction of respiratory lung motion for image-guided radiotherapy: A feasibility study
Background: The aim of this work was to study the feasibility of constructing a fast thorax model suitable for simulating lung motion due to respiration using only one CT dataset. Materials and Methods: For each of six patients with different thorax sizes, two sets of CT images were obtained in single-breath-hold inhale and exhale stages in the supine position. The CT images were then ...
متن کاملImage-guided prostate radiotherapy: analysis of inter- fractional setup errors
Introduction: The accuracy of the patient setup and tumor location are major factors that determine the efficacy of radiotherapy treatment planning. In the prostate radiotherapy, reproducibility of the prostate location for each treatment fraction is problematic owing to varying filling of the rectum and bladder. According to this, the aim of this study was to measure the inte...
متن کاملMonte Carlo study of a highly efficient gas ionization detector for megavoltage imaging and image-guided radiotherapy.
The imaging characteristics of an arc-shaped xenon gas ionization chamber for the purpose of megavoltage CT imaging were investigated. The detector consists of several hundred 320 microm thick gas cavities separated by thin tungsten plates of the same thickness. Dose response, efficiency and resolution parameters were calculated using Monte Carlo simulations. The calculations were compared to m...
متن کاملMonte Carlo simulation of RapidArc radiotherapy delivery.
RapidArc radiotherapy technology from Varian Medical Systems is one of the most complex delivery systems currently available, and achieves an entire intensity-modulated radiation therapy (IMRT) treatment in a single gantry rotation about the patient. Three dynamic parameters can be continuously varied to create IMRT dose distributions-the speed of rotation, beam shaping aperture and delivery do...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Medical Physics
سال: 2015
ISSN: 0094-2405
DOI: 10.1118/1.4929978