Monte Carlo Calculations of Dosimetric Parameters for a New Design 125I Source
نویسندگان
چکیده
منابع مشابه
Monte Carlo calculations and experimental measurements of the TG‐43U1‐recommended dosimetric parameters of 125I (Model IR‐Seed2) brachytherapy source
A new design of 125I (Model IR-Seed2) brachytherapy source has been manufactured recently at the Applied Radiation Research School, Nuclear Science and Technology Research Institute in Iran. The source consists of six resin beads (0.5 mm diameter) that are sealed in a cylindrical titanium capsule of 0.7 mm internal and 0.8 mm external diameters. This work aims to evaluate the dosimetric paramet...
متن کاملA Comparison of the Dosimetric Parameters of Cs-137 Brachytherapy Source in Different Tissues with Water Using Monte Carlo Simulation
Introduction After the publication of Task Group number 43 dose calculation formalism by the American Association of Physicists in Medicine (AAPM), this method has been known as the most common dose calculation method in brachytherapy treatment planning. In this formalism, the water phantom is introduced as the reference dosimetry phantom, while the attenuation coefficient of the sources in the...
متن کاملMonte Carlo calculation of the TG-43 dosimetric parameters of a new BEBIG Ir-192 HDR source.
BACKGROUND AND PURPOSE High dose rate (HDR) brachytherapy is a highly extended practice in clinical brachytherapy today. Quality dose rate distribution datasets of the HDR sources used in a clinical treatment are required. Because of the different source designs, a specific dosimetry dataset is required for each source model. In the recently published BRAPHYQS-ESTRO Report, an overview of avail...
متن کاملA New Approach for Monte Carlo Simulation of RAFT Polymerization
In this work, based on experimental observations and exact theoretical predictions, the kinetic scheme of RAFT polymerization is extended to a wider range of reactions such as irreversible intermediate radical terminations and reversible transfer reactions. The reactions which have been labeled as kinetic scheme are the more probable existing reactions as the theoretical point of view. The ...
متن کاملتعیین پارامترهای دزیمتری یک چشمۀ طراحیشدۀ جدید 125I با مارکر Ag + Al2O3 در فانتوم آب
The purpose of this study is to determine the dosimetric parameters of a new 125I brachytherapy seed model, using Monte Carlo (MC) simulations according to the TG-43U1 recommendation. The Monte Carlo simulated dosimetric parameters of this sourse have been provided with MCNPX v.2.6 code. The source contains a cylindrical Ag+Al2O3 marker which is located at the center of the seed and onto which...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Nuclear Medicine & Radiation Therapy
سال: 2018
ISSN: 2155-9619
DOI: 10.4172/2155-9619.1000369