Monopolar coagulator for surgery with suprachoroidal access
نویسندگان
چکیده
Retinal detachment is a pathological condition that leads to vision loss without timely surgical treatment. To restore the anatomical integrity of detached retina, number interventions (Scleral Buckling, Pars Plana Vitrectomy, combined Vitrectomy/Scleral Pneumatic Retinopexy, cryo-, laser-, and electropexy) approaches damaged area are traditionally used, among which one new promising monopolar high-frequency electrocoagulation with suprachoroidal access. The advantages this method access possibility manipulations on hard-to-reach structures eye (choroid, outer parts retina macula), introduce medical drugs into space side effects. carry out such an operation, we developed (manufactured tested) electrical instrument capable restoring retina. tool working electrode, consists handle, terminal (for connecting electric cord active phase current generator) tip. rounded tip made gold ends in sphere diameter 25 G. radius round 29.0 mm, cross section 0.5 mm. allows you reach through both endovitreal accesses. shape part repeats curvature fundus eye. materials chosen for manufacture take account need its sterilization, safety ergonomics work. Keywords: retinal detachment, electrocoagulation, vitreoretinal surgery.
منابع مشابه
Suprachoroidal Devices in Glaucoma Surgery
While conventional glaucoma filtration surgery provides excellent intraocular pressure (IOP) lowering effect, this comes at the expense of significant risks. As the physiology of the suprachoroidal space has become better understood, its potential as a source for aqueous drainage has generated significant interest. This has resulted in the creation of several suprachoroidal glaucoma devices wit...
متن کاملThe Suprachoroidal Route in Glaucoma Surgery
Glaucoma surgeries targeting the uveoscleral drainage pathways have been drawing more attention lately. Among all the available techniques, procedures focusing on the supra-choroidal space seem particularly promising, by making use of a presumably efficient and secure outflow route and avoiding subconjunctival filtration blebs. The purpose of this review is to assess the efficacy and the securi...
متن کاملThe past , present , and future of surgery for suprachoroidal drainage
T argeting the suprachoroidal space with surgery is not a new idea. All ophthalmologists are aware of the effect on intraocular pressure (IOP) of a cyclodialysis cleft following trauma. A small gap between the iris root and the scleral spur can cause devastating hypotony and be difficult to manage. In 1900, Ernst Fuchs, MD,1 and Leopold Heine, MD,2 both described the inadvertent and deliberate ...
متن کاملA stereotaxic apparatus for brain surgery and high frequency coagulator with automatic thermocontrol.
Many kinds of operation methods and apparatuses have been reported for the stereoencephalotomy. These apparatuses are discussed regarding the stability and accuracy in inserting an electrode to the target and easiness to handle. Several methods for destroying target point are compared on preciseness in controlling size of lesion, complications and prognosis. From this points of view a new stere...
متن کاملfacilitating lexical access for the fluent production of speech
the hypothesis is that recent and frequent exposure to lexical items leads to a more fluent production of speech in terms of rate of speech. to test the hypothesis , a one- way anova experimental design was carried out. 24 senior student of efl participated in a one-way interview test. data analyses revealed that those who were exposed frequently to the lexical items over a week prior to inte...
15 صفحه اولذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: ???????? ???????? ? ??????
سال: 2021
ISSN: ['2414-4495']
DOI: https://doi.org/10.35339/msz.2021.90.3.sse