Monocular dot-density cues in random-dot stereograms

نویسندگان

چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monocular dot-density cues in random-dot stereograms

In the original random-dot stereograms (RDSs) invented by Julesz, binocular disparity could only take on values that were integral multiples of dot width. The other common method for constructing RDSs (the projection method) relaxes this restriction. However, the projection method can introduce dot-density cues into the monocular images. When polar projection is employed, density variation is i...

متن کامل

Depth without disparity in random-dot stereograms.

Depth can be perceived in random-dot stereograms in which dots are binocularly uncorrelated, in the absence of overall positional disparity (e.g., Julesz, 1960). This phenomenon, which we have called rivaldepth, persists over a wide range of luminances, stereogram dot densities, and dot sizes. Rivaldepth is also observed with interocular uncorrelation provided by complementation and orthogonal ...

متن کامل

Perceptual artifacts in random-dot stereograms.

Unrestricted positioning of elements in random-dot stereograms with steep disparity gradients, such as stereo-transparent stereograms depicting overlaid surfaces, can produce perceptual artifacts similar to disparity noise. It is shown that these artifacts hinder the segregation of overlaid surfaces in transparent random-dot stereograms and thus disrupt the perception of stereotransparency. Thi...

متن کامل

fo r solving random - dot stereograms

This report examines a number of parallel algorithms for solving random-dot stereograms. A new class of algorithms based on the Boltzmann Machine is introduced and compared to previously developed algorithms. The report includes a review of the stereo correspondence problem and of cooperative techniques for solving this problem. The use of energy functions for characterizing the computational p...

متن کامل

Vergence amplitudes with random-dot stereograms.

Random-dot stereograms were found to be capable of producing fusional vergence amplitudes in the absence of monocular contours. These vergence amplitudes are not an artefact of monocular contours provided by the target borders or test instrument and are comparable in range to vergence amplitudes measured clinically with second degree fusion targets in an amblyoscope. We conclude that diplopia o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Vision Research

سال: 1996

ISSN: 0042-6989

DOI: 10.1016/0042-6989(95)00124-7