Monochromator for Aberration-Corrected STEM

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monochromator for Aberration-Corrected STEM

In a scanning transmission electron microscope (STEM), the elemental analysis at atomic resolution is realized by the combination with electron energy-loss spectroscopy (EELS), since an aberration corrected probe forming lens system enables us to obtain an electron probe sized about 0.1 nm [1]. In EELS, the energy resolution is mainly limited by the energy spread of the electron source, which i...

متن کامل

High-energy-resolution monochromator for aberration-corrected scanning

Supplementary data 367.1903.3683.DC1.html http://rsta.royalsocietypublishing.org/content/suppl/2009/08/11/ "Audio Supplement" References l.html#ref-list-1 http://rsta.royalsocietypublishing.org/content/367/1903/3683.ful This article cites 33 articles, 3 of which can be accessed free Rapid response 1903/3683 http://rsta.royalsocietypublishing.org/letters/submit/roypta;367/ Respond to this articl...

متن کامل

Hitachi’s Spherical Aberration Corrected STEM: HD-2700

INTRODUCTION AS VLSI (very large scale integration) technology evolves toward ever smaller features and multilayer designs, analysis and control of structures and compositions at the atomic level is becoming increasingly important. In 1998 Hitachi HighTechnologies Corporation released the HD-2000, a STEM (scanning transmission electron microscope) that was very well received for combining the e...

متن کامل

Aberration corrected STEM of iron rhodium nanoislands

Iron-rhodium (FeRh) nanoislands of equiatomic composition have been analysed using scanning transmission electron microscopy (STEM) electron energy loss spectroscopy(EELS) and high angle annular dark field (HAADF) techniques. Previous magnetometry results have lead to a hypothesis that at room temperature the core of the islands are antiferromagnetic while the shell has a small ferromagnetic si...

متن کامل

High-energy-resolution monochromator for aberration-corrected scanning transmission electron microscopy/electron energy-loss spectroscopy.

An all-magnetic monochromator/spectrometer system for sub-30 meV energy-resolution electron energy-loss spectroscopy in the scanning transmission electron microscope is described. It will link the energy being selected by the monochromator to the energy being analysed by the spectrometer, without resorting to decelerating the electron beam. This will allow it to attain spectral energy stability...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Microscopy and Microanalysis

سال: 2014

ISSN: 1431-9276,1435-8115

DOI: 10.1017/s1431927614004759