Monitoring of Heat Treatment Processes by High Energy Synchrotron Radiation
نویسندگان
چکیده
منابع مشابه
Nuclear Fluorescence Using High-energy Synchrotron Radiation
We present some measurements of nuclear fluorescence which were made while exploring the potential of a unique source of very hard x-rays which was installed at ESRF until recently. It produced radiation of energies up to 1MeV. In this range there are many nuclear resonances, and so we made a small survey of some plausible candidates to see if they could indeed be excited using this source. Alo...
متن کاملWater-cooled Heat Load Chopper for High-energy Synchrotron Experiments
FIGURE 2. Traditional X-ray scattering experiment setup. Photo Credit: Argonne National Laboratory. In addition to the setup shown in Figure 2, time resolution at BioCARS is provided by precise synchronization of additional beam blocking equipment placed before the sample under test—two rotating disk choppers and a shutter [2]. The X-ray beam is intercepted by a watercooled heat load chopper wh...
متن کاملBent-crystal monochromators for high-energy synchrotron radiation.
Two kinds of monochromators covering the energy ranges 100-150 keV and approximately 300 keV have been designed for inelastic (Compton) scattering experiments at the elliptical multipole wiggler beamline, BL08W, of SPring-8. Finite-element analyses using ANSYS for bent crystals indicate that thermal problems are not serious for the 300 keV monochromator, while an energy spread of about 10(-3) f...
متن کاملTexture and Microstructure Analysis with High-energy Synchrotron Radiation
Diffraction of high-energy synchrotron radiation with wavelengths in the range of 0.1Ǻ, provided by the beamline BW5 at HASYLAB in Hamburg, was used to measure textures (orientation distribution) and microstructures (spatial distribution) of the crystallites in various polycrystalline materials. In order to achieve extremely high angularcombined with very high lateral resolution a continuous sw...
متن کاملHigh Energy Synchrotron Diffraction
High energy synchrotron diffraction is introduced as a new method for residual stress analysis in the bulk of materials. It is shown that energy dispersive measurements are sufficiently precise so that strains as small 10-4 can be determined reliably. Due to the high intensity and the high parallelism of the high energy synchrotron radiation the sample gauge volume can be reduced to approximate...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Acta Physica Polonica A
سال: 2012
ISSN: 0587-4246,1898-794X