Monitoring Neonatal Peripheral Circulation by Electrocardiogram-to-Oximeter Pulse Velocity

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved Filtering of Pulse Oximeter Monitoring Alarms in the Neonatal ICU: Bedside Significance.

BACKGROUND The OxiMax N-600x containing SatSeconds alarm management software was designed to assist clinicians in discriminating nuisance alarms from those that are clinically relevant. Instead of sounding an alarm the moment the oxygen saturation reading violates the upper or lower limit settings, a magnitude and duration of tolerance can be set. The primary objective was to study the proporti...

متن کامل

An Overview on Heart Rate Monitoring and Pulse Oximeter System

Use of technology in healthcare is growing importance as a result of the tendency to acquire chronic disease like heart attack and high blood pressure. Heart rate and blood oxygen saturation is a couple of such biometrics that is monitored in this project to provide information regarding the health of the body. By measuring the intensity change of light transmitted through tissue due to arteria...

متن کامل

Pulse Oximeter Calibrator

........................................................................................................................................................ 5 Table of Figures ............................................................................................................................................ 6 Table of Tables .....................................................................

متن کامل

A Pulse Oximeter

The objective of this work was to develop a prototype for a pulse oximeter. Given the necessity, in most medical interventions, to monitorize Oxygen saturation in peripheral blood (SpO2) a pulse oximeter is highly necessary in any operating room or intensive care unit. The electronic device was built recurring mostly to Integrated Circuit (IC) and its control was performed via a programmed micr...

متن کامل

AWearable Pulse Oximeter

Group Members: Fanpeng Kong, Yubo Qin, Zhengyu Yang and Zhongtian Lin Advisor: Prof. Laleh Najafizadeh Introduction The aim of this project is to design a wearable pulse oximeter which is capable of measuring the heart-rate and blood’s oxygen saturation. The project employs wearable electronics. The project consists of three main parts: 1) sensor design, which includes the optical transceiver u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Pediatric Research

سال: 1993

ISSN: 0031-3998,1530-0447

DOI: 10.1203/00006450-199306000-00024