We present a new method to measure the modulation transfer function (MTF) beyond the Nyquist frequency of a multichannel imaging system for which all the channels have parallel optical axes. Such a multichannel optical system produces a set of undersampled subimages. If the subimages contain nonredundant information, high spatial frequencies are folded between low spatial frequencies, leading t...
متن کاملMultichannel ECG measurement system
Multichannel ECG is an important instrumentation for experimental and clinical electrophysiology. Both the software and the front-end design issues are described for a 128 channel system which can record the signals up to 100 seconds. The basic analysis and presentation of the acquired ECG signals are also given with examples of body surface potential maps. Thanks to the frequency response of t...
متن کاملMeasurement and compensation of printer modulation transfer function
bstract. The capacity of a printing system to accurately reproduce etails has an impact on the quality of printed images. The ability of system to reproduce details is captured in its modulation transfer unction (MTF). In the first part of this work, we compare three exsting methods to measure the MTF of a printing system. After a horough investigation, we select the method from Jang and Alleac...
متن کاملA formula for the mean human optical modulation transfer function as a function of pupil size.
We have constructed an analytic formula for the mean radial modulation transfer function of the best-corrected human eye as a function of pupil diameter, based on previously collected wave front aberrations from 200 eyes (Thibos, Hong, Bradley, & Cheng, 2002). This formula will be useful in modeling the early stages of human vision.
متن کاملModulation Transfer Function Measurement Using Three- and Four-bar Targets.
Modulation-transfer-function (MTF) measurement often involves the use of three- and four-bar resolution targets. In the conversion of three- and four-bar image data to MTF, biased results can occur when we use series-expansion techniques appropriate for square-wave targets of infinite extent. For systems where the image data are digitally recorded, a convenient and accurate conversion of bar-ta...