MODULATION LASER SPECTROSCOPY METHOD FOR IR-RADIATION LOSES MEASUREMENTS IN GASES
نویسندگان
چکیده
منابع مشابه
Modulation cancellation method for laser spectroscopy
We report on novel methods employing a modulation cancellation technique which result in a significantly increase in the sensitivity and accuracy of trace gas detectors. This method can be applied for isotopomer abundance quantification, temperature measurements and the detection of large molecules.
متن کاملExternal-Cavity Quantum Cascade Laser Spectroscopy for Mid-IR Transmission Measurements of Proteins in Aqueous Solution.
In this work, we report mid-IR transmission measurements of the protein amide I band in aqueous solution at large optical paths. A tunable external-cavity quantum cascade laser (EC-QCL) operated in pulsed mode at room temperature allowed one to apply a path length of up to 38 μm, which is four times larger than that applicable with conventional FT-IR spectrometers. To minimize temperature-induc...
متن کاملShort-Path Near-Infrared Laser Detection of Environmental Gases by Wavelength-Modulation Spectroscopy
The detection of environmental gases, 12CO2, 13CO2, and CH4, using near-infrared semiconductor lasers with a short laser path length is studied by means of wavelength-modulation spectroscopy. The developed system is compact and has high sensitivity enough to detect the absorption peaks of isotopic 13CO2 of a 3-% CO2 gas at 2 μm with a path length of 2.4 m, where its peak size is two orders of m...
متن کاملField detection of CO and CH4 by NIR 2f modulation laser spectroscopy
A novel compact fiber-coupled NIR system based on a DFB diode laser source is employed as a portable and sensitive gas sensor for trace detection of combustion pollutant molecules. We demonstrate the performance of such an NIR gas sensor by tracing the absorption lines of CO and CH4 using 2f-WMS technique at moderate temperature of T ~ 600°C in the recuperator channel of an industrial furnace...
متن کاملWavelength-modulation-spectroscopy for real-time, in situ NO detection in combustion gases with a 5.2 μm quantum-cascade laser
A mid-infrared absorption strategy with calibration-free wavelength-modulation-spectroscopy (WMS) has been developed and demonstrated for real-time, in situ detection of nitric oxide in particulate-laden combustionexhaust gases up to temperatures of 700 K. An externalcavity quantum-cascade laser (ECQCL) near 5.2 μm accessed the fundamental absorption band of NO, and a wavelength-scanned, 1f -no...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Sensor Electronics and Microsystem Technologies
سال: 2014
ISSN: 2415-3508,1815-7459
DOI: 10.18524/1815-7459.2014.2.108163