Modular hadron calorimeter
نویسندگان
چکیده
منابع مشابه
CMS Central Hadron Calorimeter
We present a description of the CMS central hadron calorimeter. We describe the production of the 1996 CMS hadron testbeam module. We show the results of the quality control tests of the testbeam module. We present some results of the 1995 CMS hadron testbeam. The design of the CMS detector starts with the 4 T solenoidal magnet of length 13 m and inner diameter 5.9 m. The magnet determines many...
متن کاملThe gain monitoring system of the Aleph Hadron Calorimeter
A. Messineo , G. Raso , A. Antonelli , C. Avanzini , G. Bagliesi , G. Bencivenni , F. Bossi , U. Bottigli , C. Bradaschia , P. Campana , G. Capon , F. Cerutti , V. Chiarella , D. Creanza , M. de Palma , B. D'Ettorre-Piazzoli , A. Farilla , G. Felici , L. Fo a , A. Giassi , G. Iaselli , P. Laurelli , F. Ligabue , G. Maggi , M. Maggi , E.B. Mannelli , G. Mannocchi , F. Murtas , G.P. Murtas , S. N...
متن کاملNon-Compensation of the Barrel Tile Hadron Module-0 Calorimeter
The detailed experimental information about the electron and pion responses, the electron energy resolution and the e/h ratio as a function of incident energy E, impact point Z and incidence angle Θ of the Module-0 of the iron-scintillator barrel hadron calorimeter with the longitudinal tile configuration is presented. The results are based on the electron and pion beams data for E = 10, 20, 60...
متن کاملPerformance of Hadron Calorimeter with and without HO
A study of the CMS hadron calorimeter is presented using simulated events with single particles and jets. The impact of the outer hadron calorimeter has been looked into from the point of view of linearity, energy resolution and leakage of energy. The study shows a net improvement in missing pT measurements at LHC energies due to the addition of the outer hadron calorimeter. 1) Tata Institute o...
متن کاملStudy of the CMS hadron calorimeter barrel/endcap transition region
We discuss the expected response of CMS calorimetry to single hadrons and jets in the transition region between the barrel and endcap for a number of different geometries of the ”cable path”. These results are an important element in choosing the optimal design for the hadron calorimeter in an effort to optimise the Emiss t resolution of the detector.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
سال: 1987
ISSN: 0168-9002
DOI: 10.1016/0168-9002(87)90287-7