منابع مشابه
Temporal sutureless vitrectomy in infectious scleritis with retinal detachment.
We shall like to share a novel effort, in which 23-gauge sutureless vitrectomy was done using a modified approach as an eye saving procedure. A 63-year-old male was referred after a buckling surgery done 5 days back OD. The patient had a total retinal detachment along with sloughing of the sclera in the superonasal quadrant. Microbial analysis of the slough confirmed the presence Staphylococcus...
متن کاملSutureless vitrectomy: evolution and current practices.
This review presents the evolution of sutureless vitrectomy and describes the minimisation of surgical techniques in the posterior segment, as well as their advantages and disadvantages. Shorter operating time, improvement of patient comfort and faster visual recovery are feasible when using small-diameter sutureless vitrectomy technique and equipment. However, a number of associated problems, ...
متن کاملUnexplained postoperative retinal hemorrhage after 23-gauge sutureless vitrectomy
We report five cases of unexplained retinal hemorrhage after 23-gauge sutureless vitrectomy. A 23-gauge sutureless vitrectomy was performed for four cases of macular holes (MH) and one case of macular hole retinal detachment (MHRD). Retinal hemorrhages were observed on the first day after surgery and disappeared within several months without leaving any recognizable damage. We speculate that th...
متن کاملTransconjunctival sutureless 25-gauge vitrectomy with newly designed microcannulas.
AIM To evaluate the usefulness of the newly designed 25-gauge (25-G) microcannula for transconjunctival sutureless vitrectomy (TSV). METHODS 25-G TSV was performed on 20 consecutive eyes with the newly designed 25-G microcannulas. We studied usefulness, intraoperative and postoperative complications in these cases. RESULTS No complications were recognized during surgery. Postoperative compl...
متن کاملThe Safety and Efficacy of Transconjunctival Sutureless 23-gauge Vitrectomy
PURPOSE To evaluate the efficacy and safety of vitreoretinal surgery using a 23-gauge transconjunctival sutureless vitrectomy (TSV) system for various vitreoretinal diseases. METHODS A retrospective, consecutive, interventional case series was performed for 40 eyes of 40 patients. The patients underwent vitreoretinal procedures using the 23-gauge TSV system, including idiopathic epiretinal me...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Indian Journal of Ophthalmology
سال: 2010
ISSN: 0301-4738
DOI: 10.4103/0301-4738.58489