Modified Push-out Tests for Determining Shear Strength and Stiffness of HSS Stud Connector-Experimental Study

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Push-out tests on shear studs in high strength concrete

A lot of push-out tests of shear studs embedded in normal strength concrete were conducted. So current design code methods of the shear studs are based on the test results of studs embedded in normal strength concrete. It also appeared that the strength of connector and the concrete strength are the main factors affecting the behavior of shear connections. But push-out test data of studs embedd...

متن کامل

Testing and numerical modelling of Steel-Concrete-Steel with stud bolts connectors subject to push-out loading

Steel-concrete-steel (SCS) sandwich panels are composed of two steel plates with low thicknesses and high densities and strengths and one thick layer between both plates with low strength and density known as core that is composed of concrete. Cohesive material-epoxy resin or shear connectors are usually used to connect the plates to the concrete core. SCS sandwich composites are being develope...

متن کامل

Experimental Study on the Effect of Crumb Rubber on Shear Strength of Sandy Soil

Nowadays, soil reinforcement using polymer elements have been investigated by a number of researchers in order to increase the load capacity of soils. Reinforcing soils using fibers is a method of soil improvement, which offers a homogenous mixture in combination with soils, regarding their tensile strength. This combination maintains pressure loading capacity and properties in mutual resistant...

متن کامل

Behaviour of Corroded Single Stud Shear Connectors

In this study, the effect of corrosion on the static behavior of stud shear connectors was investigated. An innovative test setup for single stud shear connectors was designed and established. Two series of specimens having different stud diameters were fabricated and tested. The test specimens were firstly corroded to different corrosion rates by the electronic accelerating method. Static load...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: International Journal of Composite Materials

سال: 2012

ISSN: 2166-479X

DOI: 10.5923/j.cmaterials.20120203.02