Modified Hertz-damp model for base-isolated structural pounding simulation under near-fault earthquakes
نویسندگان
چکیده
منابع مشابه
Structural control benchmark problem: Phase II—Nonlinear smart base-isolated building subjected to near-fault earthquakes
Many branches of engineering, mathematics, and sciences, have relied on benchmark problems as a standard means to compare different solution techniques. Since 1996, the ASCE Structural Control and Monitoring Committee and Task Group on Benchmark Problems, the U.S. Panel on structural control, and IASCM have developed a series of benchmark control problems that offer a set of carefully modeled r...
متن کاملA Hertz contact model with non-linear damping for pounding simulation
This paper investigates the cogency of various impact models in capturing the seismic pounding response of adjacent structures. The analytical models considered include the contact force-based linear spring, Kelvin and Hertz models, and the restitution-based stereomechanical approach. In addition, a contact model based on the Hertz law and using a non-linear hysteresis damper (Hertzdamp model) ...
متن کاملExperimental Study of Sliding Base-Isolated Buildings with Magnetorheological Dampers in Near-Fault Earthquakes
The increase in bearing displacements of sliding isolated buildings due to near-fault earthquakes, with long-period pulse type of ground motion, is an important problem. Often, supplemental nonlinear passive dampers are incorporated into the isolation system to reduce the base displacements; however, this may increase the interstory drifts and accelerations in the superstructure. Hence, there i...
متن کاملPerformance assessment of buildings isolated with S-FBI system under near-fault earthquakes
This study investigates the optimum design parameters of a superelastic friction base isolator (S-FBI) system through a multi-objective genetic algorithm to improve the performance of isolated buildings against near-fault earthquakes. The S-FBI system consists of a flat steel-PTFE sliding bearing and superelastic NiTi shape memory alloy (SMA) cables. Sliding bearing limits the transfer of shear...
متن کاملInfluence of Seismic Pounding on RC Buildings with and without Base Isolation System Subject to Near-Fault Ground Motions
Building pounding occurs between two adjacent buildings with small gap or without sufficient separation distance. It leads to damage buildings during earthquake due to impact. Many researchers have investigated building pounding based on impact force reduction and energy dissipation increase, when two buildings collide with each other. In numerical investigations, using specific link element, i...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Vibroengineering
سال: 2017
ISSN: 1392-8716