Modelling the Biological Beamline at HIMAC using Geant4
نویسندگان
چکیده
منابع مشابه
Therapy at HIMAC
The HIMAC (Heavy Ion Medical Accelerator in Chiba) facility is the first heavy-ion synchrotron complex dedicated to medical use in a hospital environment. As a part of ‘the Comprehensive 10-year Strategy for Cancer Control’ begun by the Japanese Government in 1984, the project for construction of the HIMAC was carried out at National Institute of Radiological sciences (NIRS), Science and Techno...
متن کاملBiological XAFS at the BioCAT Undulator Beamline 18ID at the APS
The Biophysics Collaborative Access Team (BioCAT) undulator beam line at the Advanced Photon Source, Argonne, IL is a user facility devoted to the study of partially ordered and disordered biological materials by X-ray scattering, diffraction and absorption spectroscopy. Two sagital focussing, double-crystal (Si(111) and Si(400)) monochromators and a 1 mmirror provide monochromatic, horizontall...
متن کاملPresent Status of Himac at Nirs
Since 1994 clinical trials have been performed successfully with carbon beam. To improve the clinical result further, new irradiation systems are under development such as a 3D-irradiation system and a verification system of range with positron emitter. There are also improvements on the accelerator performances. One is the wide range of ion species; the others are concerned with the machine de...
متن کاملElectron Cooling Experiments at Himac Synchrotron
Electron-cooling experiments have been carried out at the HIMAC synchrotron in order to develop new technologies in heavy-ion therapy and related researches. The cool-stacking method, in particular, has been studied to increase the intensity of heavy-ions. The simulation was carried out to optimise the cool-stacking under various injection periods. Further, the beam heating by RF-KO was applied...
متن کاملMicrofocusing at the PG1 beamline at FLASH
The Kirkpatrick-Baez (KB) refocusing mirror system installed at the PG1 branch of the plane-grating monochromator beamline at the soft X-ray/XUV free-electron laser in Hamburg (FLASH) is designed to provide tight aberration-free focusing down to 4 µm × 6 µm full width at half-maximum (FWHM) on the sample. Such a focal spot size is mandatory to achieve ultimate resolution and to guarantee best p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Physics: Conference Series
سال: 2019
ISSN: 1742-6588,1742-6596
DOI: 10.1088/1742-6596/1154/1/012003