Modelling Recharge from Irrigation Developments with a Perched Water Table and Deep Unsaturated Zone
نویسندگان
چکیده
منابع مشابه
Artificial recharge through a thick, heterogeneous unsaturated zone.
Thick, heterogeneous unsaturated zones away from large streams in desert areas have not previously been considered suitable for artificial recharge from ponds. To test the potential for recharge in these settings, 1.3 x 10(6) m(3) of water was infiltrated through a 0.36-ha pond along Oro Grande Wash near Victorville, California, between October 2002 and January 2006. The pond overlies a regiona...
متن کاملEffect of Water Table Fluctuation on Barometric Pumping in Soil Unsaturated Zone
An analytical one-dimensional model for vertical transmission of barometric pressure in soil unsaturated zone has been developed to examine the effect of free boundary caused by water table. The model is applicable to a special case in which the water table moves in according to the pressure with high barometric efficiency. Ambient sinusoidal pressure fluctuation is assumed at the soil surface....
متن کاملGroundwater recharge simulation using a coupled saturated-unsaturated flow model
Abstract The coupled MODFLOW-HYDRUS software package was used to produce a saturated-unsaturated flow model for a Flood Spreading System (FSS) and its associated aquifer. The study aim to improve simulations of near-surface hydrological processes, including temporal and spatial variation in groundwater recharge rates. The coupled model was built with average RMSE=1.1 and 1.3 for calibration ...
متن کاملOne-dimensional airflow in unsaturated zone induced by periodic water table fluctuation
[1] This paper investigates the vertical airflow driven by fluctuating water table within the lower layer of a coastal two-layered system. The upper layer is unsaturated and semipermeable, while the lower is permeable. An analytical solution of the subsurface air pressure fluctuation is derived on the basis of model simplification assumptions, the reasonability of which was examined by numerica...
متن کاملEvaluation of the response of a water table to a variable recharge rate
A new method of evaluation of the response of a water table to artificial recharge is presented. The solution is formulated in the form of a simple numerical model. The model has several advantages over the traditional methods of mounding prediction. The effect of the unsaturated zone, which modifies the recharge rate as compared with the infiltration rate, is considered. Mounding is calculated...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Water
سال: 2020
ISSN: 2073-4441
DOI: 10.3390/w12040944