Modeling the electrical energy discharged by lightning flashes using capacitors for application with lightning datasets
نویسندگان
چکیده
Abstract This study employed a parallel plate capacitor model by which the electrostatic energy of lightning flashes could be estimated considering only their physical dimensions and breakdown electric fields in two simulated storms. The has previously been used to approximate total stormelectrostatic but is modified here use geometry individual mimic local charge configuration where were initiated. discharged may then diagnosed without context storm’s entire structure. was evaluated using from storms modeled National Severe Storms Laboratory’s Collaborative Model for Multi-scale Atmospheric Simulation (COMMAS). Initial estimates followed temporal evolution flash discharge COMMAS each storm demonstrated need account an adjustment factor represent fraction dissipates, as this assumes pre-flash flash. Individual values obtained simply ratio energy. Median selected populations storm, range = 0.019−0.021. Application aligned magnitudes those previous studies. Therefore, within , application observed datasets suggested.
منابع مشابه
NO signatures from lightning flashes
In situ measurements of cloud properties, NO, and other trace gases were made in active thunderstorms by two research aircraft. Concurrent measurements from a three-dimensional (3-D) VHF interferometer and the 2-D National Lightning Detection Network were used to determine lightning frequency and location. The CHILL Doppler radar and the NOAA-WP-3D Orion X band Dopper radar were also used to me...
متن کاملAn Analysis of the Lightning Jump Algorithm Using Geostationary Lightning Mapper Flashes
This project aims to implement the two-sigma lightning jump algorithm (LJA) developed using Lightning Mapping Arrays (LMAs), with GOES-16 Geostationary Lightning Mapper (GLM) flashes, evaluate its performance, and identify any needed adjustments to the algorithm to optimize operational skill. The GLM is projected to have lower detection efficiency (DE) (7090 percent) than operational LMAs (95-9...
متن کاملElectrical and lightning injuries.
The pathophysiology, types, and treatment of electrical and lightning injuries are discussed in detail. Cases of electrical injury almost always eventually involve litigation. Therefore, careful charting of history and physical findings may save the physician court time later. Care of lightning injuries is very different from that of high voltage injuries.
متن کاملElectrical thunderstorm nowcasting using lightning data mining
This paper presents a study developed at SIMEPAR (Paraná state weather service) using lightning data for electrical thunderstorm nowcasting. Thunderstorm electrical data collected at SIMEPAR such as lightning location, time of occurrence, current intensity, polarity, etc, are stored in real-time in a relational database. As a first step of this study, Microsoft Business Intelligence bundled wit...
متن کاملElectrical Injuries and Lightning Strikes
Electrical burn injuries account for about 5% of burns unit admissions. Electricians and linesmen are at highest risk but those working with electrical tools also form a significant proportion of this patient group. [2] Electrical injuries in children are unusual and are mainly due to misguided exploration outside the home. [3] For every death, there are two serious injuries and 36 reported ele...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Atmospheric Sciences
سال: 2021
ISSN: ['1520-0469', '0022-4928']
DOI: https://doi.org/10.1175/jas-d-21-0073.1