Modeling of breath methane concentration profiles during exercise on an ergometer
نویسندگان
چکیده
منابع مشابه
Modeling of breath methane concentration profiles during exercise on an ergometer.
We develop a simple three compartment model based on mass balance equations which quantitatively describes the dynamics of breath methane concentration profiles during exercise on an ergometer. With the help of this model it is possible to estimate the endogenous production rate of methane in the large intestine by measuring breath gas concentrations of methane.
متن کاملModeling the dynamic of breath methane concentration profiles during exercise on an ergometer
We develop a simple model based on mass balance equations which describes the dynamic of breath methane concentration profiles during exercise on an ergometer. With the help of this model it is possible to calculate the endogenous production of methane in the large intestine by measuring breath gas concentration of methane.
متن کاملExhaled methane concentration profiles during exercise on an ergometer.
Exhaled methane concentration measurements are extensively used in medical investigation of certain gastrointestinal conditions. However, the dynamics of endogenous methane release is largely unknown. Breath methane profiles during ergometer tests were measured by means of a photoacoustic spectroscopy based sensor. Five methane-producing volunteers (with exhaled methane level being at least 1 p...
متن کاملIsoprene and acetone concentration profiles during exercise on an ergometer.
A real-time recording setup combining exhaled breath volatile organic compound (VOC) measurements by proton transfer reaction-mass spectrometry (PTR-MS) with hemodynamic and respiratory data is presented. Continuous automatic sampling of exhaled breath is implemented on the basis of measured respiratory flow: a flow-controlled shutter mechanism guarantees that only end-tidal exhalation segments...
متن کاملOn-Line Measurement of Dissolved Methane Concentration During Methane Fermentation in a Loop Bioreactor
A dissolved methane sensor based on silicone tube was designed, constructed and optimized.The silicone tube diameter, silicone tube length and helium flow rate (as the carrier gas(were considered as process parameters to be optimized.A continuous stream of helium (50 mL/min) was directed through the tubing, sweeping out the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Breath Research
سال: 2016
ISSN: 1752-7163
DOI: 10.1088/1752-7155/10/1/017105