Modeling of a Spray Assisted Natural Draft Cooling Tower
نویسندگان
چکیده
منابع مشابه
Snowfall observations from natural-draft cooling tower plumes.
During the winter of 1975-1976, snowfall from the plumes of large natural-draft cooling towers of power plants has been observed. Snow accumulations up to 2.5 centimeters have been found on the ground at extended distances from the cooling towers, and visibility has been restricted to less than 1600 meters in the tower plume near ground level.
متن کاملInkjet Assisted Spray Cooling of Electronics
Increases in microprocessor power dissipation and the resulting effect on the cost and complexity of thermal management solutions has been well documented in recent years. Accompanying this increase in overall power dissipation has been a reduction in feature size due to process improvements resulting in a steady decrease in the size of the processing core where most of the power on a die is ge...
متن کاملA Comprehensive Approach to an Optimum Design and Simulation Model of a Mechanical Draft Wet Cooling Tower
The present paper describes the designing of a thermally and economically optimum mechanical draft counter-flow wet cooling tower. The design model allows the use of a variety of packing materials in the cooling tower toward optimizing heat transfer. Once the optimum packing type is chosen, a compact cooling tower with low fan power consumption is modelled within the known design variables....
متن کاملNumerical and Analytical Study of Natural Dry Cooling Tower in a Steam Power Plant
Design of a natural dry cooling tower has been accomplished in two sections: the design of heat exchangers and the numerical solution of flow through the tower. Heat exchanger (Heller type) has been simulated thermodynamically and then coupled with a computer program, which calculated the turbulent natural convection flow through the tower. The computer program developed for this purpose can be...
متن کاملNumerical and Analytical Study of Natural Dry Cooling Tower in a Steam Power Plant
Design of a natural dry cooling tower has been accomplished in two sections: the design of heat exchangers and the numerical solution of flow through the tower. Heat exchanger (Heller type) has been simulated thermodynamically and then coupled with a computer program, which calculated the turbulent natural convection flow through the tower. The computer program developed for this purpose can be...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Tanzania Journal of Engineering and Technology
سال: 2008
ISSN: 2619-8789,1821-536X
DOI: 10.52339/tjet.v31i1.423