MODELING OF A DOUBLE CIRCULATION RECUPERATOR’S HEAT WORK
نویسندگان
چکیده
Utilization of heat from waste products units’ combustion is one the most important means saving fuel and energy resources improving environmental performance enterprise. Improving design recuperators increasing their efficiency by thermal based primarily on development new improvement existing methods for calculating exchangers. In this paper, method elementary balances, a mathematical model operation double-circulation recuperator developed. The use described recuperator’s work makes it possible to analyze its in terms efficiency, durability, ability reduce emissions into environment.
منابع مشابه
Laminar Flow Heat Transfer of a Pseudoplastic Fluid through a Double Pipe Heat Exchanger
An experimental study was carried out to obtain the mean convective heat transfer coefficient of aqueous carboximethyl cellulose (CMC) solutions in double-pipe heat <span style="font-size: 10pt; color:...
متن کاملAn experimental investigation of heat transfer of Fe2O3/Water nanofluid in a double pipe heat exchanger
One way to increase the heat transfer is to use perforated twisted tapes with different hole diameters, which largely improve heat transfer with an increase in the heat transfer area at the constant volume and more mixed flow. In the previous studies, the effect of nanofluids with perforated twisted tapes is less studied. In this work, the performance of water / iron oxide nanofluid in a double...
متن کاملAn experimental investigation of heat transfer of Fe2O3/Water nanofluid in a double pipe heat exchanger
One way to increase the heat transfer is to use perforated twisted tapes with different hole diameters, which largely improve heat transfer with an increase in the heat transfer area at the constant volume and more mixed flow. In the previous studies, the effect of nanofluids with perforated twisted tapes is less studied. In this work, the performance of water / iron oxide nanofluid in a double...
متن کاملThe Overall Heat Transfer Characteristics of a Double Pipe Heat Exchanger: Comparison of Experimental Data with Predictions of Standard Correlations
The single-phase flow and thermal performance of a double pipe heat exchanger are examined by experimental methods. The working fluid is water at atmospheric pressure. Temperature measurements at the inlet and outlet of the two streams and also at an intermediate point half way between the inlet and outlet is made, using copper-constantan thermocouple wires. Mass flow rates for each stream are ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: ??????? ???????? ????? ??????????????????? ?????????? ?????????? ????????????
سال: 2021
ISSN: ['2519-2884', '2617-8389']
DOI: https://doi.org/10.31319/2519-2884.38.2021.13