Modeling of 420 kV GIS Substation and Research on Very Fast Transient Overvoltage (VFTO)
نویسندگان
چکیده
منابع مشابه
Study on Very Fast Transient Overvoltage of Closing No-load China UHV Transmission Demonstration Project Jindongnan-Nanyang- Jingmen 1000 kV Transmission Lines
When the ultra high voltage (UHV) substation used the gas insulated switchgear (GIS) system to switch lines with capacitive current, the pre-breakdown and multiple reignition will occur between switching contacts. Because of discharge characteristics of SF6 and special structures of GIS system, the variations of the electromagnetic transient process and very fast transient overvoltage (VFTO) ar...
متن کاملNanocrystalline to Suppress VFTO and VFTC for 245kV Gas Insulated Substations
Switching of disconnectors (DS) and various faults in Gas Insulated Substation (GIS) causes number of pre-strikes and re-strikes happens. The short duration voltage collapse, traveling surges in busbar causes Very Fast Transient Over voltages (VFTO) and Very fast Transient Currents (VFTC) in the GIS substation. The main challenge is to reduce VFTO and VFTC amplitudes. Several methods have been ...
متن کاملStudy on Lightning Intruding Overvoltage in Yantan Extension Substation
500kV substation is especially important to the grid of our country, once it encounters lightning damage, the safety and reliability of the whole power system will be directly affected. As lightning intruding waves will cause overvoltage on electric equipments by intruding from the transmission line or straightly stroking the substation, which seriously influences the insulation level of equipm...
متن کاملHV Substation Overvoltage Computation Taking into Account Frequency Dependent Transients on the Substation Grounding System
This paper describes methodology for the computation of the electromagnetic transients in the high voltage substations, taking into account transients on the substation grounding system. Simulation technology is based on the system decomposition. Interconnections between different subsystems are done in each time step using Thevenin equivalents. Frequency dependent impedance of grounding conduc...
متن کاملEffect of Very Fast Transient over voltages at high frequency in a Gas Insulated Substation during switching operations
Due to the opening or closing of circuit breakers and disconnect switches in Gas Insulated Substations (GIS), especially in the pumped storage power stations, Very Fast Transient Over-voltages (VFTO) are generated. This paper describes the 500 kV and 750 kV GIS. The variations of VFTO magnitudes at different points in 500 kV and 750 kV GIS during different switching operations have been calcula...