A Generalized Design of Decoupling Multivariable Control for Disturbance Rejection

In this paper, a systematic procedure is proposed for the generalized design of decoupling multivariable controller, which may result in a complete decoupling, partial decoupling or no decoupling, to achieve a better disturbance rejection response. Before the decoupling, a relative load gain (abbr. RLG) is defined to determine which control loops need to be decoupled and which control loops don...

متن کامل

Active Disturbance Rejection Control Tuning Employing the Lqr Approach for Decoupling Uncertain Multivariable Systems

 The ADRC tuning is essentially a pole-placement technique and the desired performance is indirectly achieved through the location of the closed-loop poles. However, the final choice of these poles becomes a trial-and-error strategy. In contrast with pole-placement, in the LQR method, the desired performance objectives are directly and globally addressed by minimizing a quadratic function of ...

متن کامل

Optimal Control of Nonlinear Multivariable Systems

This paper concerns a study on the optimal control for nonlinear systems. An appropriate alternative in order to alleviate the nonlinearity of a system is the exact linearization approach. In this fashion, the nonlinear system has been linearized using input-output feedback linearization (IOFL). Then, by utilizing the well developed optimal control theory of linear systems, the compensated ...

متن کامل

Voltage Control of Three Phase Inverters by Using Active Disturbance Rejection Control

Control of three phase inverters has been an important issue in recent years. This paper proposes active disturbance rejection control (ADRC) scheme for controlling three phase inverters. The main advantage of ADRC that motivated us for using this controller for inverter is that it is model independent.  This controller is used in a double loop structure including an inner current loop and oute...