Modeling and experimental analysis of U-shaped segmented unidirectional heat pipe array cogeneration unit
نویسندگان
چکیده
منابع مشابه
Experimental Investigation of Heat Transfer Enhancement in a Finned U-Shaped Heat Pipe of CPU Cooling System Using Different Fluids
This paper experimentally studies the heat absorption performance of a heat sink with vertical embedded heat pipes in the aluminum blade. The cooling system with embedded heat pipes distributes heat from the CPU to both the base plate and the heat pipes, and then transfer heat from fins to the Environment. The thermal resistance and heat transfer coefficient are evaluated for natural convection...
متن کاملImprovements of U-pipe Borehole Heat Exchangers
3 PREFACE 4 ACKNOWLEDGEMENTS 5 PUBLICATIONS 6 ABBREVIATIONS AND NOMENCLATURE 7 TABLE OF CONTENTS 10 INDEX OF FIGURES 11 INDEX OF TABLES 14 1 INTRODUCTION – BASIC CONCEPTS 15 1.1 GROUND SOURCE HEAT PUMPS 15 1.2 THERMAL PROCESSES IN THE GROUND 18 1.3 SECONDARY WORKING FLUID FLOW 20 1.3.1 Hydrodynamic considerations 21 1.3.2 Thermal considerations 21 1.4 THERMAL RESISTANCES IN BHES 23 1.5 ...
متن کاملDevelopment of a meter-scale U-shaped Oscillating Heat Pipe for GAPS
Thermal performance of a 6m-long Oscillating Heat pipe (OHP) for balloon-borne General Anti-Particle Spectrometer (GAPS) experiment has been investigated. The developed OHP is a closed loop type and U-shaped due to the mission detector requirements. R410A is selected as the working fluid for the use at low temperature. We achieved a thermal conductance of 18.7 W/K for 150 W heat input with 16 t...
متن کاملExperimental Analysis of Solar Water Heater Using Pulsating Heat Pipe
Solar energy is used for solar water heater in domestic and industrial purpose. Pulsating heat pipe is a fast responding, flexible and high performance thermal conducting device. The CLPHP system described in this study relies on the natural forces of gravity and capillary action and does not require an external power source. The flat plate collector consisted of a 2 mm thick sheet of Aluminum ...
متن کاملModeling and thermal parametric analysis of U-pipe evacuated tube solar collector for four different climates in Iran
In this study, thermal performance of the collector with analytic and quasi-dynamic method is evaluated based on energy balance equations for each part of the U-pipe evacuated tube solar collector. Using this approach, effect of different parameters such as tube size, overall heat loss coefficient, absorber tube absorptivity, mass flow rate and air layer thermal resistance on thermal performanc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Case Studies in Thermal Engineering
سال: 2021
ISSN: 2214-157X
DOI: 10.1016/j.csite.2021.101074