Model System Supported Impedance Simulation of Composite Electrodes
نویسندگان
چکیده
منابع مشابه
Composite electrodes with carbon supported Ru nanoparticles for H2O2 detection.
A new carbon paste electrode (CPE) incorporating Ru - nanoparticles (RuNP) stabilized on graphite powder was developed for H(2)O(2) amperometric detection. Cyclic voltammetric measurements, performed in phosphate buffer solutions at different potential scan rates and different potential ranges were carried out in order to evaluate the electrochemical behavior of the CPE-RuNP modified electrodes...
متن کاملA Mathematical Model for the AC Impedance of Semiconducting Electrodes
A mathematical model is developed to calculate the impedance response of a semiconductor electrode to a sinusoidal current perturbation. The model accounts explicitly for electron and hole transport as well as generation and recombination through band-to-band mechanisms and through bulk interband electron acceptors of specified energy. The resistive (real) component of the impedance is shown to...
متن کاملModel of an Interdigitated Electrodes System for Cell Counting Based on Impedance Spectroscopy
Introduction: A cell counter sensor based on impedance spectroscopy has been modeled by means of COMSOL Multyphisics 4.2a. The cell counter consists in a system of vertical interdigitated electrodes, built on a silicon wafer by means of microfabrication technologies (Figure 1). With the aim to overcome the critical limiting factor of the low throughput characterizing the existing cell counters,...
متن کاملsimulation and design of electronic processing circuit for restaurants e-procurement system
the poor orientation of the restaurants toward the information technology has yet many unsolved issues in regards to the customers. one of these problems which lead the appeal list of later, and have a negative impact on the prestige of the restaurant is the case when the later does not respond on time to the customers’ needs, and which causes their dissatisfaction. this issue is really sensiti...
15 صفحه اولElectrical impedance tomography system based on active electrodes.
Electrical impedance tomography (EIT) can image the distribution of ventilated lung tissue, and is thus a promising technology to help monitor patient breathing to help selection of mechanical ventilation parameters. Two key difficulties in EIT instrumentation make such monitoring difficult: (1) EIT data quality depends on good electrode contact and is sensitive to changes in contact quality, a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Fuel Cells
سال: 2019
ISSN: 1615-6846,1615-6854
DOI: 10.1002/fuce.201800198