Modal analysis of HPGe detector assembly in gamma-ray spectrometers
نویسندگان
چکیده
منابع مشابه
Gamma-ray imaging with coaxial HPGe detector
We report on the first experimental demonstration of Compton imaging of gamma rays with a single coaxial high-purity germanium (HPGe) detector. This imaging capability is realized by two-dimensional segmentation of the outside contact in combination with digital pulse-shape analysis, which enables to image gamma rays in 4p without employing a collimator. We are able to demonstrate the ability t...
متن کاملLarge Volume HgI2 Gamma-Ray Spectrometers
This paper demonstrates the enhanced capability of single polarity charge sensing, the 3-dimensional position sensing technique, developed at the University of Michigan and previously successfully demonstrated on CdZnTe detectors, to improve the spectroscopic performance of HgI2 and to extend its range for spectrometry to an unprecedented thickness of 10 mm. Energy resolutions of close to 1% FW...
متن کاملThe Agile Gamma-ray Detector
The gamma-ray detector AGILE, operating in the energy range from 30 MeV to 50 GeV, is composed by a tracking part, a light calorimeter and an anticoincidence system. Here we describe the detector and its capabilities to determine the arrival direction and energy of the detected photons. The AGILE design is derived from a refined study of the GILDA project (Barbiellini et al. 1995, Morselli et a...
متن کاملCharge Collection Characteristics of Frisch Collar CdZnTe Gamma Ray Spectrometers
A collimated Au source was used to determine the charge collection efficiency (CCE) at several locations along the length of a 3.4 x 3.4 x 5.5 mm CdZnTe bar detector both in planar configuration and with Frisch collars of varying length. For each configuration, a 0.50 mm long region spanning the width of the device was irradiated with 411 keV gamma rays produced by a neutron activated gold foil...
متن کامل3-D position sensitive CdZnTe gamma-ray spectrometers
Two 3-D position-sensitive room temperature semiconductor c-ray spectrometers have been built using 1 cm3 cubic CdZnTe crystals. The lateral coordinates of c-ray interaction are obtained from the location of the 11(x)]11(y) pixellated anodes and the depth (z) is obtained from the ratio of the signals coming from the cathode and the anode. Energy spectra from 662keV incident c-rays have been col...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Vibroengineering PROCEDIA
سال: 2017
ISSN: 2345-0533
DOI: 10.21595/vp.2017.19205