Mitigation of Sub-Synchronous Control Interaction in Wind Power systems with GA-SA tuned Damping Controller
نویسندگان
چکیده
منابع مشابه
wind farm impact on generation adequacy in power systems
در سال های اخیر به دلیل افزایش دمای متوسط کره زمین، بشر به دنبال روش های جایگزین برای تامین توان الکتریکی مورد نیاز خود بوده و همچنین در اکثر نقاط جهان سوزاندن سوخت های فسیلی در نیروگاه های حرارتی به عنوان مهم ترین روش تولید توان الکتریکی مطرح بوده است. به دلیل توجه به مسایل زیست محیطی، استفاده از منابع انرژی تجدید پذیر در سال های اخیر شدت یافته است. نیروگاه های بادی به عنوان یک منبع تولید توان...
15 صفحه اولApplication of an Additive Self-tuning Controller for Static Synchronous Series Compensator for Damping of Sub-synchronous Resonance Oscillations
In this paper, an additive self-tuning (ST) control scheme is presented for a static synchronous series compensator (SSSC) to improve performance of conventional PI control system for damping sub-synchronous resonance (SSR) oscillations. The active and reactve series compensation are provided by a three-level 24-pulse SSSC and fixed capacitor. The proposed ST controller consists of a pole shift...
متن کاملNonlinear Analysis of Interaction with SVC in Stressed Power Systems: Effect of SVC Controller Parameters
In this paper, the effect of Static VAr Compensator (SVC) parameters on the nonlinear interaction of steam power plant turbine-generator set is studied using the Modal Series (MS) method. A second order representation of a power system equipped with SVC is developed and then by MS method the nonlinear interaction of torsional modes is assessed under various conditions and the most influencing f...
متن کاملDamping analysis of sub-synchronous resonance (SSR) in a wind farm based on DFIG in a series compensated network
The effect of wind generator on sub-synchronous resonance (SSR) is being interested by increasing penetration of wind turbine in power systems,. Purpose of this article is to analyze SSR in a wind farm based on doubly fed induction generator (DFIG) which is connected to compensating series grid. A dynamic model for analysis of induction generator effect and Torsional Interaction (TI) has been u...
متن کاملDamping of Power System Sub-Synchronous Resonance Oscillations through Fuzzy-Logic Dynamic Brake Control
Dynamically switched resistor banks connected to the generator transformer bus are known to improve transient stability of the power system. In this article, a braking resistor control strategy designed through fuzzy logic control theory has been proposed to damp the slowly growing subsynchronous resonant (SSR) frequency oscillations of a power system. The proposed control has been tested on th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IFAC-PapersOnLine
سال: 2017
ISSN: 2405-8963
DOI: 10.1016/j.ifacol.2017.08.1730