Abstract Seismic-induced pounding between adjacent buildings may have serious consequences, ranging from minor damage up to total collapse. Therefore, researchers try mitigate the problem using different methods, such as coupling with stiff beams, connecting them viscoelastic links, and installing damping devices in each building individually. In current paper, effect of linear nonlinear fluid viscous dampers mutual a series structures is investigated. Nonlinear finite-element analysis steel equipped was conducted. Contact surfaces both contactor target were used model pounding. The results indicate that use or leads significant reduction response series. Moreover, substantial improvement performance has been observed for almost all stories. From design point view, it concluded implemented should be designed resist maximum force 6.20 1.90 times independent case dampers, respectively. Also, designers pay attention structural elements surrounding because considerable forces due occur at displaced position structure.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Seismic Response Study of Asymmetric Systems with Linear and Nonlinear Fluid Viscous Dampers

This investigation is concerned with application of nonlinear fluid viscous dampers for asymmetric-plan systems. For this purpose, the behavior of nonlinear fluid viscous dampers is summarized first followed by the effects of damper nonlinearity on seismic response of asymmetric systems. It is shown that the peak force in nonlinear damper tends to be smaller compared to linear damper. However, ...

متن کامل

OPTIMUM LAYOUT OF NONLINEAR FLUID VISCOUS DAMPER FOR IMPROVEMENT THE RESPONSES OF TALL BUILDINGS

The utilization of passive energy dissipation systems has been created a revolution in the structural engineering industry due to their advantages. Fluid Viscous Damper (FVD) is one of these control systems. It has been used in many different industries, such as the army, aerospace, bridge, and building structures. One of the essential questions about this system is how it can combine with the ...

متن کامل

Seismic Design of Multi-story Buildings with Metallic Structural Fuses

Seismic design relies on inelastic deformations through hysteretic behavior. However, this translates into damage on structural elements, permanent system deformations following an earthquake, and possibly high cost for repairs. An alternative design approach is to concentrate damage on disposable and easy to repair structural elements (i.e., “structural fuses”), while the main structure is des...

متن کامل

Exploring the Efficiency of Dampers for Repair and Strengthening of Existing Buildings

In this paper, seismic behavior of the existing buildings equipped by friction dampers is studied. Seismic performance of6-story, 9-story and 12-story steel buildings with damper and without damper were studied. The finite element modeling technique (SAP2000 Software) is used for analysis. Time History analyzing was done to achieve this purpose. For nonlinear dynamic analysis, the responses of ...

متن کامل

the study of bright and surface discrete cavity solitons dynamics in saturable nonlinear media

امروزه سالیتون ها بعنوان امواج جایگزیده ای که تحت شرایط خاص بدون تغییر شکل در محیط منتشر می-شوند، زمینه مطالعات گسترده ای در حوزه اپتیک غیرخطی هستند. در این راستا توجه به پدیده پراش گسسته، که بعنوان عامل پهن شدگی باریکه نوری در آرایه ای از موجبرهای جفت شده، ظاهر می گردد، ضروری است، زیرا سالیتون های گسسته از خنثی شدن پراش گسسته در این سیستم ها بوسیله عوامل غیرخطی بوجود می آیند. گسستگی سیستم عامل...