Minimum Thickness of Long Span RC Deck Slabs for Composite 2-girder Bridges Designed by KL-510 Load Model
نویسندگان
چکیده
منابع مشابه
Finite element investigation of the structural behaviour of deck slabs in composite bridges
This research studies the structural behaviour of bridge deck slabs under static patch loads in steel–concrete composite bridges and investigates compressive membrane action (CMA) in concrete bridge decks slabs,which governs the structural behaviour. A non-linear 3D finite element analysismodels was developed using ABAQUS 6.5 software packages. Experimental data from one-span composite bridge s...
متن کاملFatigue Response of Bridge Deck Link Slabs Designed with Ductile Engineered Cementitious Composite (ECC)
Link slabs designed for macroscopically crack free concrete bridge decks system were experimentally tested. The property requirements of the link slab material were considered. Special focus was placed on the fatigue and durability performance. Introduction of a ductile Engineered Cementitious Composite (ECC) material is proposed for its ability to control crack width and to exhibit high ductil...
متن کاملPerformance of Bridge Deck Link Slabs Designed with Ductile ECC
This paper presents an experimental study on the monotonic and fatigue behavior of a link slab designed for a durable concrete bridge deck system. The requirements on the link slab in terms of material properties, dimensions, and reinforcement detailing are considered. Special focus is placed on the deflection capacity of the link slab and its fatigue performance. This paper discusses the choic...
متن کاملLong Span Bridges
Population growth followed by the dramatic increase and demand for new services created an urgent and overwhelming need for infrastructures of civil engineering structures. However, the current infrastructure work using various techniques and conventional materials for construction will not solve the traditional and continuous deterioration of concrete structures due to corrosion of steel. One ...
متن کاملStatic Instability Analysis of Long-Span Cable-Stayed Bridges with Carbon Fiber Composite Cable under Wind Load
In this paper, a three dimensional analysis is performed to investigate the static instability of long-span cable-stayed bridges due to wind loading. Cables made of carbon fiber composite cable (CFCC) are studied. Nonlinearity due to displacement-dependent wind loading is considered. A 1400meter cable-stayed bridge model is used to investigate the static behavior of bridges with both steel and ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Korean Society of Safety
سال: 2014
ISSN: 1738-3803
DOI: 10.14346/jkosos.2014.29.3.072