Minimizing Thermal Stress for Data Center Servers through Thermal-Aware Relocation

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Minimizing Thermal Stress for Data Center Servers through Thermal-Aware Relocation

A rise in inlet air temperature may lower the rate of heat dissipation from air cooled computing servers. This introduces a thermal stress to these servers. As a result, the poorly cooled active servers will start conducting heat to the neighboring servers and giving rise to hotspot regions of thermal stress, inside the data center. As a result, the physical hardware of these servers may fail, ...

متن کامل

iTad: I/O Thermal Aware Data Center Model

With the ever-growing cooling costs of largescale data centers, thermal management must be adequately addressed. Thermal models can play a critical role in thermal management that helps in reducing cooling costs in data centers. However, existing thermal models for data centers can overload I/O activities. To address this issue, we developed an I/O-aware thermal model called iTad for data cente...

متن کامل

Thermal-Aware Cell and Through-Silicon-Via

Existing thermal-aware 3D placement methods assume that the temperature of 3D ICs can be optimized by properly distributing the power dissipations, and ignoring the heat conductivity of though-silicon-vias (TSVs). However, our study indicates that this is not exactly correct. While considering the thermal effect of TSVs during placement appears to be quite complicated, we are able to prove that...

متن کامل

Thermal spatio-temporal data for stress recognition

Stress is a serious concern facing our world today, motivating the development of a better objective understanding through the use of non-intrusive means for stress recognition by reducing restrictions to natural human behavior. As an initial step in computer vision-based stress detection, this paper proposes a temporal thermal spectrum (TS) and visible spectrum (VS) video database ANUStressDB ...

متن کامل

Challenges of data center thermal management

The need for more performance from computer equipment in data centers has driven the power consumed to levels that are straining thermal management in the centers. When the computer industry switched from bipolar to CMOS transistors in the early 1990s, low-power CMOS technology was expected to resolve all problems associated with power and heat. However, equipment power consumption with CMOS ha...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Scientific World Journal

سال: 2014

ISSN: 2356-6140,1537-744X

DOI: 10.1155/2014/684501