Minimizing Pulling Geometry Errors in Atomic Force Microscope Single Molecule Force Spectroscopy
نویسندگان
چکیده
منابع مشابه
Minimizing pulling geometry errors in atomic force microscope single molecule force spectroscopy.
In atomic force microscopy-based single molecule force spectroscopy (AFM-SMFS), it is assumed that the pulling angle is negligible and that the force applied to the molecule is equivalent to the force measured by the instrument. Recent studies, however, have indicated that the pulling geometry errors can drastically alter the measured force-extension relationship of molecules. Here we describe ...
متن کاملPulling geometry-induced errors in single molecule force spectroscopy measurements.
In AFM-based single molecule force spectroscopy, it is tacitly assumed that the pulling direction coincides with the end-to-end vector of the molecule fragment being stretched. By systematically varying the position of the attachment point on the substrate relative to the AFM tip, we investigate empirically and theoretically the effect of the pulling geometry on force-extension characteristics ...
متن کاملSingle molecule force spectroscopy in biology using the atomic force microscope.
The importance of forces in biology has been recognized for quite a while but only in the past decade have we acquired instrumentation and methodology to directly measure interactive forces at the level of single biological macromolecules and/or their complexes. This review focuses on force measurements performed with the atomic force microscope. A general introduction to the principle of actio...
متن کاملForce Spectroscopy with the Atomic Force Microscope
Introduction and Review Atomic Force Microscope (AFM) Spectroscopy is an AFM based technique to measure, and sometimes control the polarity and strength of the interaction between the AFM tip and the sample. Although the tip-sample interaction may be studied in terms of the energy, the quantity that is measured first is always the tip-sample force, and thus the nomenclature: force spectroscopy....
متن کاملOptimizing 1-μs-Resolution Single-Molecule Force Spectroscopy on a Commercial Atomic Force Microscope
Atomic force microscopy (AFM)-based single-molecule force spectroscopy (SMFS) is widely used to mechanically measure the folding and unfolding of proteins. However, the temporal resolution of a standard commercial cantilever is 50-1000 μs, masking rapid transitions and short-lived intermediates. Recently, SMFS with 0.7-μs temporal resolution was achieved using an ultrashort (L = 9 μm) cantileve...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Biophysical Journal
سال: 2008
ISSN: 0006-3495
DOI: 10.1529/biophysj.108.138842