Microwave Dielectric Measurement of Liquids by using Waveguide Plunger Technique

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microwave Dielectric Measurement of Solids and Liquids over 1 to 4 Ghz Using Transmission Line Technique and Coaxial Cavity

Accurate microwave dielectric measurement of materials is necessary data for the design engineer during the development stage of electronic and communication components. Several techniques have been published in recent years for measurement of dielectric properties of materials at microwave frequencies. Each of these techniques has some limitations in terms of accuracy and frequency coverage. T...

متن کامل

Microwave Characterization of Frequency and Temperature Dependences of Beef Bone Dielectric Properties Using Waveguide Measurement System

The article focuses on the measurement and calculation of dielectric properties of biological tissue in the frequency band 4,5 GHz – 16 GHz. Special attention is paid to the frequency and thermal dependence dielectric constant and loss factor. Observed frequency changes of biological tissue dielectric properties obey causality, i.e. Kramers-Krönig relationships which relate changes of dielectri...

متن کامل

The Measurement of Dielectric Properties of Liquids at Microwave Frequencies Using Open-ended Coaxial Probes

Significant progress has been made in recent years in the development of microwave tomographic imaging systems for medical applications. In order to design an appropriate microwave imaging system for industrial applications, and to interpret the images produced, the materials under imaging need to be characterised. In this paper, we describe the use of open-ended coaxial probes for the measurem...

متن کامل

Measurement of Complex Permittivity of Liquids Using Waveguide Techniques

Complex permittivity of a number of liquids and binary mixtures has been studied by measurement using the waveguide techniques at the X and Ku band. Particular pieces of WR90 and WR62 waveguides were designed for the measurement of liquid materials. The custom designed TRL calibration kits are applied for calibration of the waveguide system. The measured results of complex permittivity of liqui...

متن کامل

A Modified Formula for Microwave Measurement of Dielectric Loss Using a Closed Cylindrical Cavity Dielectric Resonator

This paper provides a modified formula for calculating dielectric loss of dielectric resonator of working in TE01δ mode in closed cavity. The measurement system is divided into six regions. Based on analyzing the formula of loss tangent published in literatures, a quality factor of a substrate is created, and a modified formula is proposed. Validating the modified formula, with three substrates...